摘 要:目的研究免散瞳眼底照相法应用于糖尿病视网膜病变筛查工作中发挥的作用。方法选择本院247例糖尿病患者,针对其开展直接检眼镜眼底检查(直接眼底镜组),之后再进行免散瞳眼底照相检查(免散瞳眼底照相组),分析两种检查方式的应用效果。结果免散瞳眼底照相法在检查敏感性和特异性上均优于直接眼底镜检查法,差异有统计学意义(P<0.05);免散瞳眼底照相法在卡帕检验一致性上均优于直接眼底镜检查法,差异有统计学意义(P<0.05)。结论针对糖尿病患者选择免散瞳眼底照相检查方法进行检查能够发挥良好应用效果。Objective To study the clinical effect of free mydriatic fundus photography for diabetic retinopathy screening work. Methods 247 cases of diabetes patients, direct ophthalmoscope group was carried out about the examination of direct ophthalmoscope, then non-mydriatic fundus camera inspection group was carried out about the examination of nonmydriatic fundus photography, to analyze the application effect of two types of inspection. Results The sensitivity and specificity of free mydriatic fundus photography on the inspection were better than those of the direct ophthalmoscope test, the difference was statistically significant(P〈0.05); The method of free of mydriatic fundus photography on the consistency of capa tests were better than that of the direct ophthalmoscope test(P〈0.05).Conclusion Free mydriatic fundus camera inspection for patients with diabetes have a good the value of application.