检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]中国石油兰州润滑油研究开发中心,新疆克拉玛依834003 [2]中国石油润滑油重点实验室,新疆克拉玛依834003
出 处:《润滑油》2016年第3期54-60,共7页Lubricating Oil
摘 要:文章分别在交流、直流和交直流混合电场下建立变压器油击穿电压的测试方法。在极不均匀电场下,开展变压器油烃组成与其击穿电压的相关性研究。研究结果表明,在极不均匀交流电场下,变压器油的击穿电压与其烃组成没有相关性。在极不均匀直流和交直流混合电场下,变压器油的击穿电压与其烃组成有相关性,变压器油芳烃含量(C_A值)越高,正负极性击穿电压越低;在相同油间隙下,负极性击穿电压高于正极性击穿电压。随着油间隙的增加,击穿电压值增加。In this paper,test methods for breakdown voltage of transformer oils in the AC electric field,DC electric field and AC/DC complex electric field were established.In the highly non- uniform electric field,correlation study between hydrocarbon compositions and breakdown voltage of transformer oils was carried out.Research results show that,in the current highly non- uniform AC electric field,breakdown voltage of transformer oils and their hydrocarbon components haven't great relevance.In the current highly non- uniform DC electric field and AC/DC complex electric field,breakdown voltage of transformer oils and their hydrocarbon components have a great relevance.Aromatic hydrocarbons content in transformer oils(C_A value) is higher,positive and negative polarity breakdown voltage is lower.In the same oil gap,negative polarity breakdown voltage is higher than the positive polarity breakdown voltage,along with the increase of oil gap,the breakdown voltage value increases.
关 键 词:交流电场 直流电场 交直流混合电场 变压器油 烃组成 击穿电压
分 类 号:TE626.3[石油与天然气工程—油气加工工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.30