反渗透系统保安过滤器滤芯污堵原因分析及处理  被引量:19

Cause analysis on the pollution and blockage in the security filter core of reverse osmosis system and its treatment

在线阅读下载全文

作  者:刘向朝[1] 陈玉琨 

机构地区:[1]中海油天津化工研究设计院有限公司,天津300131 [2]大唐内蒙古多伦煤化工有限责任公司,内蒙古多伦010206

出  处:《工业水处理》2016年第6期99-102,共4页Industrial Water Treatment

摘  要:福建某新材料公司脱盐水系统在运行一段时间后,其反渗透系统保安过滤器滤芯出现污堵,影响了脱盐水系统的正常运行。对污堵原因进行了分析,并提出了相应的改进措施。改进措施实施后,彻底解决了反渗透保安过滤器滤芯的污堵问题,脱盐水产水率得以恢复。After the desalted water system of a new material company in Fujian,China has run for a period of time,pollution and blockage occur to the security filter core of the reverse osmosis system,affecting the normal operation of the desalted water system. The causes of pollution and blockage are analyzed and corresponding improving measures are put forward. After the improving measures have been implemented,the pollution and blockage problems of reverse osmosis security filter core are solved completely. As a result,the water yield of desalination water can be restored.

关 键 词:反渗透 保安过滤器滤芯 微生物污染 还原剂 

分 类 号:TK223.5[动力工程及工程热物理—动力机械及工程]

 