摘 要:目的:建立注射用三磷酸腺苷二钠氯化镁中氯化镁含量测定的原子吸收法。方法:采用火焰原子吸收标准曲线法,检测波长为285.2 nm。结果:镁离子在浓度0.12~0.28μg· mL-1的范围内,线性关系良好( r=0.9998),精密度、回收率良好。结论:该方法可以准确测定注射用三磷酸腺苷二钠氯化镁中氯化镁含量,不受其他成分的影响,可用于注射用三磷酸腺苷二钠氯化镁的质量控制。Objective:To establish an AAS method for determining the content of Magnesium Chloride in Adenosine Disodium Triphos -phate and Magnesium Chloride for Injection.Method:A calibration curve method of flame atomic absorption spectrometry was adopt-ed.The detection wavelength was set at 285.2 nm.Results:The concentration of Magnesium had a good linearity in the range of 0.12-0.28 μg· mL-1(r=0.999 8), the precision and recovery rate was good.Conclusion:The method is accurate and do not be inter-fered by other ingredients.It can be used for the quality control of Adenosine Disodium Triphosphate and Magnesium Chloride for Injec -tion.
关 键 词:原子吸收法 注射用三磷酸腺苷二钠氯化镁 氯化镁 含量测定