摘 要:运用全自动消解—ICP-MS对5种不同茶叶16种稀土元素(Sc,Y,La,Ce,Pr,Nd,Sm,Eu,Gd,Tb,Dy,Ho,Er,Tm,Yb,Lu)进行检测.结果表明,方法相关系数为0.999 7~0.999 9,检出限低,一般都在ng/L级别,加标回收率和精密度(RSD)分别为92.9%~110.7%和0.24%~4.41%.5种茶叶稀土氧化物总量为0.749~3.486 mg/kg,其中轻稀土元素(La,Ce,Pr,Nd,Sm)和Y含量较高,占稀土总量的80%以上.此方法操作简便,准确度和精密度高,是检测不同茶叶中稀土元素含量的一种可行性方法 .Five different types of tea were decomposed with full automatic digestion,and 16 REEs( Sc,Y,La,Ce,Pr,Nd,Sm,Eu,Gd,Tb,Dy,Ho,Er,Tm,Yb,Lu) were analyzed by ICP-MS. The results showed that the correlation coefficients are 0. 999 7—0. 999 9 with low detection limit at the level of ng / L. The recoveries and precisions are 92. 9% —110. 7% and 0. 24% —4. 41% respectively. The contents of the rare earth oxides are 0. 749—3. 486 mg / kg in tea samples,and the content of LREEs( La,Ce,Pr,Nd and Sm) and Y is relatively high,accounting for more than 80% of the total REEs. This is a simple and feasible method with high accuracy and high precision to analyze the content of REEs in different kinds of tea.