检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张中
机构地区:[1]陕西省西安市第九医院眼科,陕西西安710054
出 处:《中国CT和MRI杂志》2016年第9期19-21,共3页Chinese Journal of CT and MRI
摘 要:目的评价多层螺旋CT(multislice spiral computed tomography,MSCT)三维重建对眼部异物的定位价值。方法选取2013年8月到2015年12月期间来我院就诊的可疑眼部异物患者74例(74只眼),进行眼眶DR拍摄和MSCT三维重建,比较两种方法眼部异物的检出率;眼眶-DR法拍摄阳性患者行角膜-DR定位法,测量出异物与水平面、矢状面、角巩膜缘距离。结果 74例患者经手术确诊69例存在眼部异物,MSCT三维重建法检测异物28例,检出率37.84%;眼眶DR法检出异物21例,检出率28.38%,经比较差异有统计学意义(P=0.003);21例眼眶DR法检测出异物的患者MSCT均能检测出。以眼眶DR法测量值-MSCT三维重建法测量值为检验统计量,异物点钟位(0.03±0.32)mm(t=1.296,P>0.05),异物与矢状面距离(0.03±0.41)mm(t=0.896,P>0.05),异物与水平面距离(0.05±0.35)mm(t=1.564,P>0.05),异物与角巩膜缘距离(0.12±0.81)mm(t=1.182,P>0.05)。结论 MSCT三维重建眼部异物检出率高,定位较为准确,对于眼部异物定位具有重要价值。Objective To evaluate the value of three-dimensional reconstruction of multislice spiral CT scan m the localization of ocular foreign body. Methods 74 cases (74 eyes) suspicious patients with oc~ foreign body were selected and accepted DR. film and MSCT three-dimensional reconstruction respectively from August 2013 to December 2015, to compare the detection rate of two methods. The location of foreign body and the distances of foreign body with sagittal, horizontal and limbus were measured. Results 69 cases were confirmed with ocular foreign body by surgery in the total 74 cases, 28 cases were diagnosed by three-dimensional reconstruction of multislice spiral CT scan, withthe detection rate of 37.84%, while 21 cases were diagnosed by orbital digital radiography, with the detection rate of 28.38%: The difference was statistical significance(P=0.003), the location of foreign body and the distances of foreign body with sagittal, horizontal and limbus measured by three-dimensional reconstruction of muttislice spiral CT scan were similar to those measured by orbital digital radiography. The differences had no statistical significance, the location of foreign body at (0.03 ±0.32) mm (t=1.296, P〉1.296), the sagittal distances of foreign body were (0.03 ± 0.41) mm (t=0.896, P〉 0.896), the horizontal distances of foreign body were (0.05 ± 0.35)mm (t=1.564, P〉1.564), the distances between foreign body were (0.12 ± 0.81) mm (t=1.182, P〉1.182) to the limbus. Conclusion The detection rate of ocular foreign body by MSCT three-dimensional reconstruction was high and with high accuracy rate, which had important value for the localization of ocular foreign body.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.200