自动控温石墨消解仪溶样-原子荧光法测定土壤中重金属  被引量:14

Automatic temperature controlled graphite digestion apparatus-AFS for determining heavy metals in soil

在线阅读下载全文

作  者:丁冬梅[1] 张赞[1] 王记鲁 李炜[1] 

机构地区:[1]天津市环境监测中心,天津300191

出  处:《分析试验室》2016年第9期1108-1110,共3页Chinese Journal of Analysis Laboratory

摘  要:采用进口自动控温石墨消解仪,在塑料管中用王水消解样品,原子荧光法测定土壤中重金属。采用这种前处理设备和消解方法,既减少了本底污染,又能使用同一份消解溶液测定多种元素,实现了快速测定的目的,加标回收率达到90%~110%。Using imported automatic temperature controlled graphite digestion apparatus,soil samples were digested in plastic tube with aqua regia,and heavy metals were measured with atomic fluorescence spectrometry(AFS). The pretreatment device and the digestion method can not only reduce the background pollution,but also detect various elements with the same digestion solution to achieve the purpose of rapid determination. The method has good accuracy,and the recovery is 90% ~ 110%.

关 键 词:原子荧光法 土壤 重金属 石墨消解仪 