Ultra-wide field imaging system and traditional retinal examinations for screening fundus changes after cataract suraery  被引量:1

Ultra-wide field imaging system and traditional retinal examinations for screening fundus changes after cataract suraery

在线阅读下载全文

作  者:Jie Peng Qi Zhang Hai-Ying Jin Wu-Yi Lu Pei-Quan Zhao 

机构地区:[1]Department of Ophthalmology,Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine

出  处:《International Journal of Ophthalmology(English edition)》2016年第9期1299-1303,共5页国际眼科杂志(英文版)

基  金:Supported by the National Natural Science Foundation of China(No.81271045;No.81470642);Shanghai Science and Technology Committee(No.15XD1502800)

摘  要:AIM:To compare the results of non-mydriatic ultra-wide field imaging system,mydriatic slit-lamp lens(Volk+90 D) and mydriatic Goldmann three-mirror contact lens examinations in screening fundus lesions among patients after cataract surgery.METHODS:Non-mydriatic images were obtained with an Optomap panoramic 200Tx(Optomap 200Tx) 3d after surgery and graded by a blinded ophthalmologist.A mydriatic slit-lamp lens examination was performed by another blinded retinal specialist on the same day.A third blinded retinal specialist examined patients two weeks after surgery using a Goldmann three-mirror contact lens.RESULTS:In total,160 patients(184 eyes) were examined,and 66,69,and 75 cases of retinal lesion(s)were identified using the Optomap 200 Tx,slit-lamp lens,and Goldmann three-mirror contact lens,respectively.In13 cases,fundus changes were sight-threatening.The results obtained by Optomap 200 Tx examination and by mydriatic slit-lamp lens examination have good consistency(P =0.375,Kappa =0.942).The mydriatic Goldmann three-mirror lens examination revealed more fundus lesions but are consistent with Optomap 200Tx(P=0.004,Kappa =0.897) and mydriatic slit-lamp lens examination(P=0.031,Kappa=0.932).CONCLUSION:Early post-operative fundus screening in cataract patients is extremely important and necessary to prevent further vision loss.Wide-field imaging is a feasible and convenient tool for fundus examination that can be used as a primary screening method among patients after cataract surgery.AIM:To compare the results of non-mydriatic ultra-wide field imaging system,mydriatic slit-lamp lens(Volk+90 D) and mydriatic Goldmann three-mirror contact lens examinations in screening fundus lesions among patients after cataract surgery.METHODS:Non-mydriatic images were obtained with an Optomap panoramic 200Tx(Optomap 200Tx) 3d after surgery and graded by a blinded ophthalmologist.A mydriatic slit-lamp lens examination was performed by another blinded retinal specialist on the same day.A third blinded retinal specialist examined patients two weeks after surgery using a Goldmann three-mirror contact lens.RESULTS:In total,160 patients(184 eyes) were examined,and 66,69,and 75 cases of retinal lesion(s)were identified using the Optomap 200 Tx,slit-lamp lens,and Goldmann three-mirror contact lens,respectively.In13 cases,fundus changes were sight-threatening.The results obtained by Optomap 200 Tx examination and by mydriatic slit-lamp lens examination have good consistency(P =0.375,Kappa =0.942).The mydriatic Goldmann three-mirror lens examination revealed more fundus lesions but are consistent with Optomap 200Tx(P=0.004,Kappa =0.897) and mydriatic slit-lamp lens examination(P=0.031,Kappa=0.932).CONCLUSION:Early post-operative fundus screening in cataract patients is extremely important and necessary to prevent further vision loss.Wide-field imaging is a feasible and convenient tool for fundus examination that can be used as a primary screening method among patients after cataract surgery.

关 键 词:CATARACT fundus screening Goldmann three-mirror contact lens Optomap 200Tx slit-lamp lens 