Nd:YAG激光照射对牙本质表面微观特征影响的实验研究  被引量:8

The experimental study on the effect of dentine micro-characteristic features after irradiating with Nd:YAG laser

在线阅读下载全文

作  者:李雪英[1,2] 孔婷婷[1] 刘莉 董少杰[1] 李晓红[1] 牛林[1,4] LI Xue-ying KONG Ting-ting L DONG Shao-jie LI Xiao-hong NIU Lin(Stomatology Hospital of Xi'an Jiaotong University College of Medicine, Shaanxi Xi'an, 710004, China Department of endodontics, Stomatological Hospi- tal of Yantai, Shandong Yantai 261000, China Department of orthodontics, Stomatological Hospital of Yantai, Shandong Yantai 261000, China Shaanxi Province Clinical Reaserch Center for Dental and Maxillofacial diseases, Stomatology Hospi- tal of Xi'am Jiaotong University, Shaanxi Xi'an, 710004, China.)

机构地区:[1]西安交通大学附属口腔医院,陕西西安710004 [2]烟台市口腔医院牙体牙髓科,山东烟台264000 [3]烟台市口腔医院正畸科,山东烟台264000 [4]陕西省牙颌疾病临床医学研究中心,陕西西安710004

出  处:《临床口腔医学杂志》2016年第9期519-522,共4页Journal of Clinical Stomatology

摘  要:目的:研究不同剂量Nd:YAG激光照射后,牙本质小管封闭深度及不同深度内钙磷比值的变化,得出Nd:YAG激光治疗牙本质过敏症的最佳参数。方法:酸蚀法建立牙本质敏感模型,应用不同参数的Nd:YAG激光照射样本,A组(0 mj,0 Hz,对照组);B组(30 mj,5 Hz);C组(30 mj,10 Hz);D组(50 mj,5 Hz);E组(50 mj,10 Hz)。照射完成后将样本纵剖,扫描电镜观察照射前后样本牙本质小管封闭深度并用X-线能谱分析不同深度处样本钙磷比值变化。结果:扫描电镜见B组牙本质小管表面封闭,近表面处小管直径比对照组变小。C、D两组牙本质小管熔融达一定厚度,且牙本质结构完整。E组牙本质熔融厚度达25μm,但熔融区中有微孔产生。X线能谱分析各组样本5μm、20μm深处的钙磷比值,差异无统计学意义。结论:Nd:YAG激光牙本质脱敏的较为理想参数为(30 mj,10Hz)和(50 mj,5 Hz)。Objective: To evaluate the dentine micro- characteristic change after irradiating with Nd: YAG laser.Methods: The dentin hypersensitivity model was setted up by Acid etching. And then the samples were irradiated by Nd:YAG laser under different parameters. The morphological alterations and the calcium- phosphorus( Ca / P) ratio in different depth of the dentin were examined with SEM combined with energy dispersive X-ray microanalysis. Results: At the longitudinal section of samples,the dentinal tubules were blocked and with smaller diameter of tubules near the dentine surface at group B compared with the control group. Dentinal tubules were blocked to a certain depth and no damage at group C and D.The tubules were blocked from surface to the 25μm deepth and had many micro- cracks around the tubules at group E.Compared with the control group,the Ca / P ratios at 5μm and 20μm deepth were a little different but there was no statistically significant( P 0. 05). Conclusion: The suitable energy parameter of Nd: YAG laser seem been 30 mj,10 Hz and 50 mj,5Hz during treating dentin hypersensitivity.

关 键 词:牙本质敏感症 ND:YAG激光 牙本质小管 钙磷比值 

分 类 号:R781.2[医药卫生—口腔医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象