A Selective and Sensitive Fluorescence Probe for Se(IV) Based on Fluorescence Quenching of Gatifloxacin  

A Selective and Sensitive Fluorescence Probe for Se(IV) Based on Fluorescence Quenching of Gatifloxacin

在线阅读下载全文

作  者:LIU Qing HUAN Yanfu ZHENG Qingchuan FEI Qiang FEI Yanqun FAN Qian FENG Guodong SHAN Hongyan 

机构地区:[1]College of Chemistry, Jilin University, Changchun 130021, P. R. China [2]Laboratory of Theoretical and Computational Chemistry, Institute of Theoretical Chemistry, Jilin University, Changchun 130021, P. R. China [3]Changchun WeiersaiBiotec Pharmaceutical Co., Ltd., Changchun 130616, P. R. China [4]Changchun Vocational Institute of Technology, Changchun 130033, P. R. China

出  处:《Chemical Research in Chinese Universities》2016年第5期736-741,共6页高等学校化学研究(英文版)

基  金:Supported by the National Natural Science Foundation of China(No.21207047), the State Major Project for Science and Technology Development, China(No.2013YQ47078102-3), the Science-Technology Development Project of Jilin Province of China(Nos.20130206014GX, 20140623007TC, 20150204017YY), the Open Project of the State Key Laboratory of Inorganic Synthesis and Preparative Chemistry, Jilin University, China(No.2014-07) and the Natural Science Foundation of Jilin Province, China(No.20160101314JC).

摘  要:A novel high selective and sensitive fluorescence probe termed gatifloxacin was discovered based on fluorescence "on-off" phenomenon in the presence of Se(IV). In the Tris-HCl/acetonitrile(3:7, volume ratio, Tris-HCl 0.05 mol/L, pH=7.3) system, the fluorescence intensity of gatifloxacin was linearly decreased with the concentration increase of Se(IV) in a range of 1.0×10-5--5.0×10-5 mol/L with a correlation coefficient of 0.9979(R2=0.9958) and in a range of 5.0×10-5--1.0 ×10-4 mol/L with a correlation coefficient of 0.9973(R2=0.9946). The detection limit of Se(IV) was 1.70×10-6mol/L.A novel high selective and sensitive fluorescence probe termed gatifloxacin was discovered based on fluorescence "on-off" phenomenon in the presence of Se(IV). In the Tris-HCl/acetonitrile(3:7, volume ratio, Tris-HCl 0.05 mol/L, pH=7.3) system, the fluorescence intensity of gatifloxacin was linearly decreased with the concentration increase of Se(IV) in a range of 1.0×10-5--5.0×10-5 mol/L with a correlation coefficient of 0.9979(R2=0.9958) and in a range of 5.0×10-5--1.0 ×10-4 mol/L with a correlation coefficient of 0.9973(R2=0.9946). The detection limit of Se(IV) was 1.70×10-6mol/L.

关 键 词:GATIFLOXACIN Fluorescence probe QUENCHING SELENIUM 