机构地区:[1]Department of Chemistry, Payame Noor University (PNU) [2]Department of Chemistry, Isfahan University of Technology
出 处:《Chinese Chemical Letters》2017年第2期240-247,共8页中国化学快报(英文版)
摘 要:In this study,Au nanoparticles/poly 5-[(2-hydroxynaphthalen-l-yl)diazenyl]isophthalic acid film modified glassy carbon electrode(AuNPs/poly(NDI)/GCE) has shown excellent electrocatalytic activity toward the oxidation of adrenaline(ADR),paracetamol(PAC),and tryptophan(Trp).The bare glassy carbon electrode(GCE) fails to separate the oxidation peak potentials of these molecules,while the poly(NDI) film modified electrode can resolve them.Electrochemical impedance spectroscopy(EIS)indicates that the charge transfer resistance of the bare electrode decreases as 5-[(2-hydroxynaphthalen-l-yl)diazenyl]isophthalic acid is electropolymerized on the bare electrode.Furthermore,EIS exhibits enhancement of electron transfer kinetics between analytes and the electrode after electrodeposition of Au nanoparticles.Differential pulse voltammetry results show that the electrocatalytic current increases linearly in the ranges of 0.01-680.0 μmol L^-1 for ADR,0.05-498.0 μmol L^-1 for PAC,and 3.0-632.0 μmol L^-1 for Trp;with detection limits(S/N = 3) of 0.009 μmol L^-1,0.005 μmol L^-1,and 0.09 μmol L^-1 for ADR,PAC,and Trp,respectively.The proposed method has been successfully applied for simultaneous determination of ADR,PAC,and Trp in biological samples.In this study,Au nanoparticles/poly 5-[(2-hydroxynaphthalen-l-yl)diazenyl]isophthalic acid film modified glassy carbon electrode(AuNPs/poly(NDI)/GCE) has shown excellent electrocatalytic activity toward the oxidation of adrenaline(ADR),paracetamol(PAC),and tryptophan(Trp).The bare glassy carbon electrode(GCE) fails to separate the oxidation peak potentials of these molecules,while the poly(NDI) film modified electrode can resolve them.Electrochemical impedance spectroscopy(EIS)indicates that the charge transfer resistance of the bare electrode decreases as 5-[(2-hydroxynaphthalen-l-yl)diazenyl]isophthalic acid is electropolymerized on the bare electrode.Furthermore,EIS exhibits enhancement of electron transfer kinetics between analytes and the electrode after electrodeposition of Au nanoparticles.Differential pulse voltammetry results show that the electrocatalytic current increases linearly in the ranges of 0.01-680.0 μmol L^-1 for ADR,0.05-498.0 μmol L^-1 for PAC,and 3.0-632.0 μmol L^-1 for Trp;with detection limits(S/N = 3) of 0.009 μmol L^-1,0.005 μmol L^-1,and 0.09 μmol L^-1 for ADR,PAC,and Trp,respectively.The proposed method has been successfully applied for simultaneous determination of ADR,PAC,and Trp in biological samples.
关 键 词:Adrenaline Paracetamol Tryptophan Au nanoparticles 5-[(2-Hydroxynaphthalen-1-yl)diazenyl]isophthalic acid Glassy carbon electrode
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...