关节镜下双空心加压螺钉内固定治疗青少年股骨髁Salter-Harris Ⅲ型骨折  被引量:2

Double hollow compression screws for treatment of Salter-Harris type Ⅲ fractures of femoral condyle in adolescents under arthroscopy

在线阅读下载全文

作  者:张洪鑫[1] 于洪昌 宋波[2] 杨晓明[1] 潘昭勋[1] 

机构地区:[1]解放军第89医院骨科研究所关节外科,山东潍坊261021 [2]潍坊职业学院信息工程学院

出  处:《中国骨与关节损伤杂志》2017年第4期351-353,共3页Chinese Journal of Bone and Joint Injury

摘  要:目的探讨关节镜下双空心加压螺钉内固定治疗青少年股骨内髁Salter-Harris Ⅲ型骨折的临床疗效。方法笔者自2006-09—2014-08诊治23例青少年股骨内髁Salter-Harris Ⅲ型骨折,在关节镜下清理复位,在骺板远端用2枚4.5 mm的空心加压螺钉固定骨折。结果23例获得随访平均15.7(12~36)个月,手术时间为(28.92±5.04)min,所有的骨折解剖复位,术后3个月获骨性愈合,术后1年肢体长度较对侧无变化。Tegar评分术前(3.00±1.65)分,末次随访为(8.00±1.24)分;Lyshlom评分术前(25.43±10.04)分,末次随访为(92.00±3.91)分,末次随访Tegar评分、Lysholm评分较术前有较大改善,差异有统计学意义(t=-26.830,P<0.001;t=-11.218,P<0.001)。末次随访膝关节主动活动度:患侧活动度为(125.65±4.28)°,健侧活动度为(126.48±4.12)°,患侧与健侧比较差异无统计学意义(t=-0.890,P=0.445)。本组皆无感染、关节纤维化、下肢深静脉血栓形成。结论关节镜下双空心加压螺钉能最大程度解剖复位并坚强固定分离的股骨内髁和关节面,具有优良的短期临床效果。Objective To investigate the clinical efficacy of arthroscopic treatment of Salter-Harris type m fractures of the femoral condyle in adolescent. Methods From September 2006 to August 2014, 23 cases of adolescent femoral condylar fractures of Salter-Harris type Ⅲ were treated, with 2 hollow compression screws (4.5 mm) fixation of the distal epiphyseal plate under arthroscopy. Results Twenty-three patients were followed up for an average of 15.7(12-36)months. The operation time was (28.92±5.04)min. All of the fractures were anatomically reduced, and the bone healing was achieved in the first 3 months after operation. The length of the limbs was unchanged one year after operation. The preoperative Tegar scores was 3.0 (3.00±1.65)points,and 8.0 (8.00±1.24)points at the final follow-up; Lyshlom score before operation was 25.4 (25.43±10.04) points,and 92.0 (92.00±3.91)points at the end of the follow-up. Tegar score and Lysholm score were greatly improved compared after operation, the difference was statistically significant (t =-26.830, P 〈0.001; t =-11.218, P 〈0.001). At the end of the follow-up, the active motion degree of the affected side was 125°(125.65±4.28) and the range of motion of the healthy side was 126°(126.48±4.12), and there was no significant difference between the affected side and the healthy side(t =-0.890, P =0.445). All the patients had no joint infection, fibrosis and lower extremity deep venous thrombosis. Conclusion Double hollow compression screws under arthroscopy can achieve the greatest degree of anatomical reduction and rigid fixation of the femoral condyle and articular surface, with excellent short-term clinical results.

关 键 词:关节镜 股骨内髁 骨骺损伤 青少年 

分 类 号:R687.3[医药卫生—骨科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象