检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王聪[1,2] 杨晶[1] 潘秀娟[1] 蔡高航 赵巍[1] 张景园[3] 崔大复[1] 彭钦军[1] 许祖彦[1]
机构地区:[1]中国科学院理化技术研究所,中国科学院固体激光重点实验室,中国科学院功能晶体与激光技术重点实验室,北京100190 [2]中国科学院大学,北京100190 [3]南佐治亚大学物理系,美国佐治亚州30460
出 处:《物理学报》2017年第10期123-129,共7页Acta Physica Sinica
基 金:中国科学院科技创新基金(批准号:CXJJ-16M112,CXJJ-15S089);北京市自然科学基金(批准号:8154055)资助的课题~~
摘 要:非线性光学相位共轭技术可将经过散射介质后产生畸变的光学波前进行修复.本文基于光参量放大(OPA)过程的光学相位共轭(OPC)特性,进行了光学相位共轭图像修复和增强的实验研究.基于大能量532 nm皮秒抽运激光和大口径非线性光学晶体KTiOPO_4(KTP)(Ⅱ类相位匹配),对经过牛奶乳浊液后已无法识别的1064 nm近红外光学图像,进行相位共轭修复,修复后的图像分辨率达12线/mm,此外,结合OPA过程的光学增益特性,实现了超过17 dB的光学图像增强,为现有三波混频光学相位共轭修复畸变所获图像增益的最大值.在此基础上,峰值信噪比较修复之前有160%的提升.考虑到光参量过程所具有的波长可调谐特性,在实际应用中,可根据需要,选择与生物组织的光学治疗窗口相匹配的成像波长,从而保证更长的穿透深度,提升生物组织成像和医学无损检测的效果.It is well known that the weak optical image can be amplified based on the optical parametric amplification (OPA), and the distorted wave-front can be recovered by the optical phase conjugation (OPC) method. In this paper, weak infrared images, which are barely recognizable after the propagation through the milk emulsion, are restored and optically amplified based on phase conjugation of OPA.#br#The OPC property of OPA is demonstrated with a type-II phase matched nonlinear optical crystal KTiOPO4 (KTP). The near-infrared image at 1064 nm is the input of OPA as the signal beam, and a 10 Hz, mJ-level, 21 ps 532 nm laser is used as the pump beam. When the spatial and temporal overlap are achieved, the attenuated optical image is amplified. Due to the difference in polarization, the idler beam of the OPA is selected and detected with the CCD and the blurred image is restored by the re-entry of the turbid media.#br#The resolution of restored image is 12 lines/mm, which has achieved a theoretical limit. Moreover, by combining the optical gain of the OPA process, over 17 dB image amplification is obtained, which is the highest for the OPC-based image restoration in turbid media to our knowledge. The significant improvement in image quality is also demonstrated by 160% increase of the peak signal-to-noise ratio. By taking advantage of tunability of the OPA, the operational wavelength of this technique can be extended to an optical therapeutic window, which is suitable for noninvasive image restoration, enhancement and detection.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.218.10.21