检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:韩玉彤 陈彬川[1] 朱光举 徐一帆[1] 雷方[3]
机构地区:[1]郑州大学第二附属医院,河南省郑州市450000 [2]新乡医学院三全学院,河南省新乡市453000 [3]河南科技大学,河南省洛阳市471000
出 处:《眼科新进展》2017年第6期562-565,共4页Recent Advances in Ophthalmology
摘 要:目的利用超声生物显微镜观察高度近视白内障患者超声乳化吸出联合人工晶状体植入术后囊袋张力环对人工晶状体倾斜度和偏心量的影响。方法选取接受白内障超声乳化吸出联合人工晶状体植入术的高度近视白内障患者36例(40眼),平均眼轴长度26.88 mm。按照术中是否植入囊袋张力环分为植入组和对照组。植入组19眼术中植入囊袋张力环,对照组21眼行常规手术。对患者行常规裂隙灯检查,记录术前、术后6个月最佳矫正视力,并于术后6个月行超声生物显微镜检查得到水平和垂直方向的倾斜度、偏心量,计算人工晶状体总的倾斜度和偏心量。结果两组术后最佳矫正视力均比术前有所提高;术前术后两组间最佳矫正视力比较,差异均无统计学意义(均为P>0.05)。植入组在水平方向、垂直方向以及总的偏心量分别为(0.15±0.07)mm、(0.30±0.40)mm、(0.11±0.02)mm,在水平方向、垂直方向以及总的倾斜度分别为0.02°±0.11°、0.70°±0.25°、0.21°±0.74°。对照组在水平方向、垂直方向以及总的偏心量分别为(0.26±0.19)mm、(0.32±0.60)mm、(0.24±0.97)mm,在水平方向、垂直方向以及总的倾斜度分别为0.11°±0.31°、1.09°±0.20°、1.24°±0.97°。两组人工晶状体水平方向的偏心量和倾斜度,垂直方向的倾斜度及总的偏心量和倾斜度差异均有统计学意义(均为P<0.01);在垂直方向上偏心量差异无统计学意义(P>0.05)。结论囊袋张力环对于白内障合并高度近视患者术后人工晶状体的位置具有稳定作用。Objective To discuss the effects of capsular tension ring after phaco- emulsification combined with IOL implantation on tilt and decentration of IOL in high myopia patients with cataract by ultrasonic biomicroscope (UBM). Methods A total of 36 cases (40 eyes) with high myopia and cataract underwent phacoemulsification combined with IOL implantation were chosen. The average axial length was 26.88 nun. The patients were divided into implant group ( 19 eyes, the capsular tension ring was im- planted) and control group (21 eyes, the routine surgery was performed). The patients were exantined by conventional slit lamp,and the best corrected visual acuity (BCVA) was measured at pre-operation and postoperative 6 months. Tilt and decentration were measured horizontally and vertically, and total tilt and decentration were calculated by geometry method. Results The postoperative BCVA in the two groups were all better than the pre-operation,there was no statistical difference in the preoperative and post- operative BCVA between two groups ( all P 〉 0.05 ). The horizontal, vertical and total decentration the implant group were ( 0. 15 ± 0.07 ) mm, ( 0. 30 ± 0.40 ) mm, ( 0. 11 ± 0.02) ram,respectively, which in the control group were (0.26 ± 0. 19 )mm, (0.32± 0. 60) nml, ( 0.24 ± 0.97 ) mm, respectively. The horizontal, vertical and total tilt in the implant group were 0.02° ± 0. 11 ° ,0.70°± 0.25° ,0.21° ± 0.74°, respectively, which in the control group were 0. 11° ± 0.31°, 1.09° ± 0.20°,1. 24 °± 0.97° , respectively. There were statistical differences in the horizontal, total tilt and decentration between two groups ( all P 〈 0.05 ), but no statistical difference in the vertical tilt and decentration (P 〉 0. 05). Conclusion The capsular tension ring can stable the IOL position after surgery in high myopia and cataract patients.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.185