检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:武洪林[1,2] 李俊[2] 李红尧[2] 魏文峰[3] 蒋兰芝 王德杭[1]
机构地区:[1]南京医科大学第一附属医院影像科,江苏南京210029 [2]江苏大学附属武进医院影像科,江苏常州213002 [3]江苏大学附属武进医院脑外科,江苏常州213002
出 处:《医学影像学杂志》2017年第7期1213-1217,共5页Journal of Medical Imaging
基 金:江苏省第四期333高层次人才培养项目[苏人才(2011)15号];江苏省常州市卫生创新人才培养工程[常卫科教(2010)368号]
摘 要:目的评估双源CT低管电压及低剂量等渗对比剂对头颈部CT血管造影图像质量和辐射剂量的影响。方法选取头颈部CTA患者60例,随机分成两组(各30例)。A组:管电压80/Sn140 k Vp,对比剂32ml(270mg I/ml)。B组:管电压100/Sn140 k Vp,对比剂40ml(370mg I/ml)。记录各段动脉CT值、噪声值、对比噪声比、信噪比,以及辐射剂量、碘摄入量、图像质量主观评分等,进行统计分析。结果除了A组的升主动脉噪声值明显高于B组(P<0.01),两组图像的血管CT值、噪声值、信噪比、对比噪声比无统计学差异(P值均>0.05)。A组辐射剂量明显低于B组,减少了23.8%(P<0.001)。A组每例患者的碘摄入量较B组下降了41.6%。两组图像质量评分无统计学差异(P=0.844)。两名医生对图像质量一致性检验的Kappa值为0.663(P<0.001)。结论双源CT低管电压及低剂量等渗对比剂可以用于头颈部CT血管造影,在满足诊断要求的基础上,能同时减少辐射剂量及碘摄入量。Objective To evaluate the image quality and radiation dose of craniocervical CT angiography (CTA) using low tube voltage and low volume of isotonic contrast material (CM).Methods A total of sixty patients who underwent craniocervical CTA were randomly assigned into 2 groups (each with 30 cases): gorup A with 80/Sn140 kVp and 32 ml of 270 mgI/ml CM, and group B with 100/Sn140 kVp and 40 ml of 370 mgI/ml CM.The CT attenuation, effective dose (ED), image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of each arterial segment were compared between the two protocols using the Student t test.Qualitative analysis between the protocols was also performed.Results Both groups of CTA achieved comparable CT attenuation, image noise, SNR and CNR in each arterial segment, except for the image noise of ascending aorta (P〈0.01).Using the double low-dose mode, the ED was reduced by about 23.8 % (P〈0.001), and iodine intake of patients in group A was reduced by 41.6%.There was no significant difference in image quality between the two groups (P=0.844).The consistency between the two observers was good (kappa value=0.663, P〈0.001).Conclusion In craniocervical dual source CTA, using low tube voltage and and low volume of isotonic CM not only provided images of diagnostic quality but also reduced both radiation dose and iodine intake.
关 键 词:头颈部 低管电压 低剂量对比剂 辐射剂量 体层摄影术 X线计算机
分 类 号:R743[医药卫生—神经病学与精神病学] R814.42[医药卫生—临床医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.219.191.41