机构地区:[1]Ophthalmic Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Lab [2]Department of Ophthalmology, Affiliated Hospital of Hebei Medical University [3]College of Applied Arts and Science, Beijing Union University
出 处:《International Journal of Ophthalmology(English edition)》2017年第9期1407-1411,共5页国际眼科杂志(英文版)
摘 要:AIM:To study the relation between higher-order aberrations(HOAs)and contrast sensitivity(CS)in normal eyes among a population of laser in situ keratomileusis(LASIK)candidates.METHODS:In 6629 eyes of 3315 LASIK candidates,CS were measured under dark environment at the spatial frequencies of 1.5,3,6,12 and 18 cycles per degree(c/d),respectively,using an Optec 6500 visual function tester.Meanwhile,ocular HOAs were measured for a 6.0 mm pupil with a Hartmann-Shack wavefront analyzer.RESULTS:In the study,the subjects with an average spherical equivalent of-4.86±2.07 D were included.HOAs decreased from the third to the sixth order aberrations with predominant aberrations of third-order coma,trefoil and fourth-order spherical aberration.At low and moderate spatial frequencies,CS was negatively correlated with the third-order coma and trefoil aberrations,and decreased with increasing Z31,but increased with increasing Z3-3and Z5-1.At high spatial frequencies,CS decreased with increasing Z3-3and increased with increasing Z5-1.CONCLUSION:At a large pupil size of 6.0 mm,the thirdorder aberrations,but not the total aberrations,are the main factors affecting CS.Vertical coma is negatively correlated with CS.AIM:To study the relation between higher-order aberrations(HOAs)and contrast sensitivity(CS)in normal eyes among a population of laser in situ keratomileusis(LASIK)candidates.METHODS:In 6629 eyes of 3315 LASIK candidates,CS were measured under dark environment at the spatial frequencies of 1.5,3,6,12 and 18 cycles per degree(c/d),respectively,using an Optec 6500 visual function tester.Meanwhile,ocular HOAs were measured for a 6.0 mm pupil with a Hartmann-Shack wavefront analyzer.RESULTS:In the study,the subjects with an average spherical equivalent of-4.86±2.07 D were included.HOAs decreased from the third to the sixth order aberrations with predominant aberrations of third-order coma,trefoil and fourth-order spherical aberration.At low and moderate spatial frequencies,CS was negatively correlated with the third-order coma and trefoil aberrations,and decreased with increasing Z31,but increased with increasing Z3-3and Z5-1.At high spatial frequencies,CS decreased with increasing Z3-3and increased with increasing Z5-1.CONCLUSION:At a large pupil size of 6.0 mm,the thirdorder aberrations,but not the total aberrations,are the main factors affecting CS.Vertical coma is negatively correlated with CS.
关 键 词:MYOPIA contrast sensitivity higher-orderaberrations COMA spherical aberration
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...