作 者:郑亚琴[1] 崔桐[1] 郑旭亮[1] 刘建庭[1] 邢晓汾[1]
机构地区:[1]山西省肿瘤医院山西医科大学附属肿瘤医院放射治疗中心,太原030013
出 处:《中华放射医学与防护杂志》2017年第9期709-712,共4页Chinese Journal of Radiological Medicine and Protection
基 金:山西省卫生计生委科研课题资助(2015057)
摘 要:目的 探讨Varian加速器不同射野形成方式对射野剂量学参数的影响,为治疗计划系统(TPS)数据建模提供理论依据。方法 在准直器(JAW)、多叶光栅(MLC)和准直器跟随多叶光栅(JAW+MLC)3种射野的形成方式下,分别测量百分深度剂量(PDD)、射野离轴量(OAR)及射野总散射因子(Scp),并对实测数据进行分析比较。结果 3种射野形成方式对中心轴的百分深度剂量影响很小;在加速器的左右方向和枪靶方向,MLC形成的射野均较JAW形成射野大,在左右方向最大可达2.9 mm。在枪靶方向,最大可达1.7 mm。在左右方向MLC形成的射野测量曲线的半影较在相同射野大小JAW形成射野的半影大。在枪靶方向MLC形成的射野测量曲线的半影较在相同射野大小JAW形成射野的半影小。在两个方向 JAW+MLC形成射野与JAW形成射野大小与半影均无明显差异。结论 射野的不同形成方式对射野大小、半影、总散射因子有影响,建议做调强放射治疗(IMRT)时,在TPS数据建模过程中,应对MLC射野的剂量参数进行关注。Objective To evaluate the influences of various field-defining method of Varian accelerator on radiation dosimetry parameters, and provide theoretical basis for the beam modeling of the treatment planning system (TPS).Methods The percentage depth dose (PDD), the off-axis ratio (OAR) and the total scattering factors (Scp) of radiation fields were measured in three different conditions, including collimators (JAW), multileaf collimator(MLC) and JAW+MLC. The measured data was analyzed and compared with each other.Results The PDD of central axis was marginally influenced by three field-defining method. In both directions, the MLC-defined field sizes were larger by a maximum of 2.9 mm (left-right) or 1.7 mm (gun-target) than the JAW-defined ones. In the left-right direction, the width of field penumbra shaped by MLC was larger than the field of the same size as defined by JAW. The result of gun-target direction was to the contrary. In both directions, the field penumbra and size displayed no significant differences as defined by JAW+MLC or JAW.Conclusions The field size, penumbra width, and the total scattering factors were influenced by field-defining method, which indicates that special attention should be paid to the dosimetric parameters of MLC during TPS beam modeling for IMRT planning.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.148.241.210