检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:杨晶[1] 王庆福[1] 王艳颖 孙晓迪 王文慧[1] 张健[1]
机构地区:[1]天津市口腔医院,南开大学附属口腔医院种植科,300041
出 处:《天津医药》2017年第10期1083-1087,共5页Tianjin Medical Journal
摘 要:目的比较先锋钻导航和全程导航导板进行不翻瓣即刻种植手术的精确性。方法回顾性分析2014—2016年天津市口腔医院种植科47例门诊即刻种植患者(50颗种植体)的资料,分别在先锋钻导航系统(22颗)和全程导航系统(28颗)的引导下行种植手术。术前拍摄锥形束CT(CBCT)并制取模型,经过三维重建、模拟种植设计以及应用数字化快速成型技术制成导板。分别应用先锋钻导航和全程导航系统配合种植钻进行窝洞预备,最后进行种植体植入手术。术后再次拍摄CBCT并进行三维重建,比较两种导航系统引导下植入体的精确性。结果 50颗种植体全部应用导板顺利完成手术,1例在临时修复3个月后出现种植体黏膜炎,经处理后完成最终修复,其余病例均顺利完成最终修复,所有植体无松动、无脱落。全程导航系统引导下的种植体植入后颈部和根端偏差均小于先锋钻导航(P<0.01),但两者轴向角度偏差差异无统计学意义(P>0.05)。结论数字化外科导板可对前牙不翻瓣即刻种植技术的应用提供良好的技术支持,全程导航系统比先锋钻导航系统具有更高的精准性。Objective To compare the operative precision between pioneer drilling guiding and full navigation guidingplates in the flapless immediate implantation. Methods Data of 50 immediate implants, which were implanted from 47 outpatients(50 implants) of Tianjin Stomatological Hospital from 2014 to 2016 were retrospectively analyzed. The patientswere conducted on the pioneer drilling guiding system(22 implants) and full navigation guiding sytem(28 implants). Thecone beam CT(CBCT) was preliminarily taken and modeled for each patient. All of the patients underwent implant surgeryafter making guiding plates by three-dimensional reconstruction, simulation planting design and the application of digitalrapid prototyping technology. Cavity preparations were made by pioneer drilling and full navigation assisted with plantingdrills respectively to finish implantation. The post-operative CBCT was taken and performed the three-dimensionalreconstruction. The implantation precision guiding by two systems were compared. Results All of the 50 immediateimplants were successfully completed with the guiding plates. Implant mucositis appeared in one case after 3 months oftemporary repair, and after the targeted therapy, the final repair was finished. The rest cases were finally completed. Noimplant was loose or fell off. The deviation was less in neck apex and root apex angle in full navigation group than that ofpioneer drilling guiding group(P < 0.01). But there was no significant difference in axial angle between the two groups afternavigation and implantation(P > 0.05). Conclusion The digital surgical guiding plates provide nice technical support forthe application of the flapless immediate implantation. And the full navigation system has higher precision than that of thepioneer drilling navigation system.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.233