检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:赵峰[1] 陆中杰[1] 姚国荣[1] 卜路懿[1] 葛迦 宁丽华[1] 严森祥[1] Zhao Feng;Lu Zhongjie;Yao Guorong;Bu Luyi;Ge Jia;Ning Lihua;Yan Senxiang(Department of Radiation Oncology, First Affiliated Hospital, College of Medicine, Zhefiang University, Hangzhou 310003, China)
机构地区:[1]浙江大学医学院附属第一医院放疗科,杭州310003
出 处:《中华放射医学与防护杂志》2017年第11期821-825,共5页Chinese Journal of Radiological Medicine and Protection
基 金:浙江省自然科学基金(LQ15H180001)
摘 要:目的 比较3种呼吸模式在左侧乳腺癌保乳术后全乳放疗中的剂量学差异,以探索能最大程度地减少靶区周围重要组织器官照射体积和剂量的呼吸模式。方法 前瞻性选取18例左侧早期乳腺癌保乳术后需行放疗的患者,采集自由呼吸(FB)、胸式深吸气屏气(T-DIBH)及腹式深吸气屏气(A-DIBH)3种呼吸模式下的CT图像,随后行适形放疗计划设计,比较3种呼吸模式下的剂量学参数,包括剂量-体积直方图、靶区平均剂量及靶区剂量均匀指数、危及器官平均剂量等。结果 3种呼吸模式下,计划靶区体积、计划靶区平均剂量及计划靶区剂量均匀指数等差异均无统计学意义(P〉0.05);FB、T-DIBH及A-DIBH3种模式下的危及器官受量在心脏Dmean分别为(3.21±1.02)、(1.74±0.51)及(1.31±0.41) Gy,差异有统计学意义(W=171,P〈0.05);冠状动脉左前降支(LAD)Dmean分别为(34.61±13.51)、(14.38±10.20)及(9.21±6.53) Gy,差异有统计学意义(W=171,P〈0.05);左侧肺Dmean分别为(8.31±2.75)、(7.46±1.96)及(6.89±1.79) Gy,差异有统计学意义(W=171,P〈0.05)。结论 两种深吸气屏气技术(T-DIBH或A-DIBH)可显著降低心脏、LAD及左肺等危及器官的照射剂量,且不影响放疗靶区剂量;而A-DIBH比T-DIBH在降低各危及器官的照射剂量方面更具优势。Objective To investigate the dosimetric differences among three types of breath hold mode (free breath:FB, thoracic deep inspiration breath hold:T-DIBH, abdomen deep inspiration breath hold:A-DIBH) and to explore the optimal breath hold method in the postoperative radiotherapy of left-side breast cancer patients with minimum dose to normal tissues and organs at risk. Methods A total of eighteen patients with left-side breast cancer patients who underwent postoperative radiotherapy were enrolled in this study. Three CT simulation scans with three different breath hold method (FB, T-DIBH, and A-DIBH) were performed for each patient. Dosimetric differences were compared among plans generated on these three different CT image sets. Results There was no significant difference in the volume, mean dose, and homogeneity of planning target volume (PTV) among plans generated from three different image sets (P〉0.05). The mean heart dose, mean LAD dose and mean ipsilateral lung dose in plans generated from CT image sets with FB, T-DIBH and A-DIBH were (3.21±1.02), (1.74±0.51),(1.31±0.41) Gy (W=171, P〈0.05), (34.61±13.51), (14.38±10.20), (9.21±6.53) Gy (W=171, P〈0.05), and (8.31±2.75), (7.46±1.96), (6.89±1.79) Gy (W=171, P〈0.05), respectively. Conclusions Compared with plans with FB, plans with DIBH (T-DIBH and A-DIBH) achieved lower cardiac, LAD and pulmonary doses. A-DIBH achieved a better normal dose reduction than T-DIBH.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.230