检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:赵欣宇[1] 赵晶[1] 顾菲[1] 纪天龙[1] 夏兵[1] 张硕[1] 姚雷[1] 李光[1]
机构地区:[1]中国医科大学附属第一医院放疗科,沈阳011001
出 处:《中华放射肿瘤学杂志》2017年第12期1421-1425,共5页Chinese Journal of Radiation Oncology
摘 要:目的 评估外照射后体积仍较大宫颈癌行三维腔内近距离放疗同步体外施源器引导下IMRT剂量学可行性。方法 用Oncentra4.3 TPS为7例外照射后体积较大的宫颈癌患者分别设计内外融合放疗计划和三维腔内放疗计划;并对同一患者4次内外融合放疗计划进行基于弹性配准的三维剂量叠加,计算OAR累积剂量,使用配对t检验或Wilcoxon符号秩检验差异。结果 内外融合计划D90、V100、CI高于三维腔内计划(P=0.000);两种计划直肠、乙状结肠和膀胱D2cc差异无统计学意义(P〉0.05);弹性配准三维剂量叠加法与DVH参数数值相加法两种OAR累积剂量计算方法计算直肠、乙状结肠、膀胱总D2cc值差异无统计学意义(P〉0.05)。结论 对外照射后体积仍较大的宫颈癌,内外融合放疗可显著提高靶区覆盖和适形度,并未明显增加OAR剂量。验证了三维叠加法与数值相加法对OAR累积剂量的评估方法的可行性。Objective To evaluate the dosimetric feasibility of three-dimensional (3D) intracavitary brachytherapy in combination with applicator-guided intensity-modulated radiation therapy (IMRT) boost for patients with locally advanced cervical cancer who have unfavorable topography following external beam irradiation. Methods A total of 7 patients with locally advanced cervical cancer who had unfavorable topography following external beam irradiation were included. Two plans were generated for brachytherapy using Oncentra 4.3 treatment planning system:3D intracavitary brachytherapy and 3D intracavitary brachytherapy in combination with applicator-guided IMRT boost. To further evaluate cumulative doses to organs at risk (OAR) in the four fractions of combined plans, two methods were used:simple dose-volume histograms (DVH) parameter addition and deformable image registration (DIR)-based DVH accumulation. The D90, V100, and conformity index (CI) were evaluated. The paired t-test or Wi1coxon signed rank test was used for statistical analysis. Results Compared with the 3D plan, the combined plan yielded higher D90, V100, and CI (P=0.000), but showed no significant difference in D2cc of the rectum, sigmoid colon, and bladder (P〉0.05). There were also no significant differences in D2cc of the rectum, sigmoid colon, and bladder calculated by the two methods for calculating OAR cumulative doses, simple DVH parameter addition and DIR-based DVH accumulation (P〉0.05). Conclusions For patients with cervical cancer who have unfavorable topography following external beam irradiation, 3D intracavitary brachytherapy in combination with applicator-guided IMRT boost can improve target coverage and CI, without increasing OAR doses. DIR-based DVH accumulation and simple DVH parameter addition may be both acceptable for assessing OAR cumulative doses.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.13