检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:赵琦 王霄娜 杨文利 魏文斌 WANG Ruikang K. 游启生 楚仲頔 辛晨 ZHAO Qi1, WANG Xiao-na1 , YANG Wen-li1, WEI Wen-bin1, WANG Ruikang K. 1,2, YOU Qi-sheng1 , CHU Zhong-di2, XIN Chen1.(1. Beijing Institute of Ophthalmology, Beifing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing Key Laboratory of Ophthalmology and Visual Sciences, Beijing 100730, China ; 2. Department of Bioengineering, University of Washington, Seattle 98195, United State)
机构地区:[1]首都医科大学附属北京同仁医院北京同仁眼科中心眼科学与视觉科学北京市重点实验室北京市眼科研究所,100730 [2]华盛顿大学生物工程系,98195
出 处:《眼科》2018年第2期107-110,共4页Ophthalmology in China
摘 要:目的评价基于光学微血流成像技术(OMAG)的相干光断层扫描血流成像(OCTA)在正常眼视网膜血流定量分析的可重复性。设计诊断试验。研究对象 40名(40眼)健康志愿者,年龄22~55岁,平均(33.0±8.8)岁。方法使用Zeiss Cirrus HD-OCT 5000扫描,以基于OMAG技术的AngioPlex^(TM)软件对视网膜浅层3 mm×3 mm OCTA图像的血流长度密度(VLD)、灌注密度(PD)及黄斑中心凹无血流信号区(FAZ)面积、周长、圆形度进行自动定量分析。采用变异系数(CV)评价观察日内及观察日间重复性,组内相关系数(ICC)评价观察者间再现性。主要指标变异系数(CV)和组内相关系数(ICC)。结果各血流参数观察日内CV(1.2±1.0)%^(4.2±5.5)%,均≤4.2%,观察日间CV(1.4±0.8)%^(4.6±4.9)%,均≤4.6%,观察日间CV高于观察日内CV,而中心凹、FAZ各参数CV高于旁中心凹CV;各血流参数观察者间ICC(0.923~0.994),均≥0.923,中心凹、FAZ各参数ICC高于旁中心凹。结论基于OMAG技术的OCTA对正常眼视网膜浅层血流各参数测量均具有较好的重复性和再现性。Objective To determine the repeatability of optical coherence tomography angiography( OCTA) based on optical microangiography( OMAG) measurements of macular vessels in normal eyes. Design Diagnosis test. Participants A total of 40 eyes of 40 normal volunteers were examined at Beijing Tongren Eye Center. The mean age was 33. 0 ± 8. 8 years( 22 ~ 55 years). Methods OCTA data was acquired using Zeiss Cirrus HD-OCT 5000 angiography system. The following parameters were used for quantitative analysis: vessel length density( VLD),perfusion density( PD) and area,perimeter,circularity of foveal avascular zone( FAZ). Main Outcome Measures The coefficient of variation( CV) and intraclass correlation coefficients( ICC). Results All parameters showed high repeatability [CV( 1. 2 ± 1. 0) % ^( 4. 2 ±5. 5) %,all ≤4. 2%( intravisit) and( 1. 4 ± 0. 8) % ^( 4. 6 ± 4. 9) %,all≤4. 6%( intervisit) ] and interobserver reproducibility( ICC = 0. 923 ~ 0. 994,all≥0. 923). The CVs were higher for intervisit than for intravisit,higher for fovea and FAZ than for parafovea. The ICCs were higher for fovea and FAZ than for parafovea. Conclusion The evidence presented here demonstrates good repeatability and reproducibility of OCTA based on OMAG for measurement of superficial vessel parameters in normal eyes.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.112