全飞秒激光小切口角膜基质透镜取出术(SMILE)角膜帽与飞秒激光辅助的准分子激光角膜原位磨镶术(FS-LASIK)角膜瓣的对比  被引量:18

Characteristics of caps created with SMILE versus flaps created with FS-LASIK

在线阅读下载全文

作  者:胡雅斌 周跃华 张晶 张丽 郑燕 刘倩 HU Ya-Bin;ZHOU Yue-Hua;ZHANG Jing;ZHANG Li;ZHENG Yan;LIU Qian

机构地区:[1]首都医科大学附属北京同仁医院北京同仁眼科中心、北京市眼科学与视觉科学重点实验室,北京市100730

出  处:《眼科新进展》2018年第9期869-872,共4页Recent Advances in Ophthalmology

摘  要:目的对比全飞秒激光小切口角膜基质透镜取出术(small incision lenticule extraction,SMILE)制作的角膜帽和飞秒激光辅助的准分子激光角膜原位磨镶术(femtosecond laser in situ keratomileusis,FS-LASIK)制作的角膜瓣的特点。方法 100例200眼近视患者根据手术方式分为SMILE组、FS-LASIK组,每组各50例100眼。SMILE组角膜帽及FS-LASIK组角膜瓣厚度均设定为110μm,RTVue-OCT测量术眼角膜0°和90°两条子午线所在截面上特定7个点的角膜帽和角膜瓣厚度值,并对角膜帽和角膜瓣上14个测量点的厚度进行对比。结果术后1周,SMILE组中央区角膜帽厚度为(109.4±2.8)μm,低于FS-LASIK组中央区角膜瓣厚度[(111.2±3.6)μm],差异有统计学意义(t=-3.062,P<0.01)。SMILE组全角膜帽厚度值为(109.3±2.1)μm,亦低于FS-LASIK组全角膜瓣厚度[(111.1±1.8)μm],差异有统计学意义(t=-5.130,P<0.01)。两组在不同离心度的位置,角膜帽和角膜瓣厚度的变异均不大。两组角膜0°和90°经线所在截面的平均角膜帽和角膜瓣厚度差异均无统计学意义(均为P>0.05)。SMILE组中与预计值差值≤5μm的有1170个测量点,而FS-LASIK组中有1226个测量点。结论SMILE制作的角膜帽与FS-LASIK制作的角膜瓣同样具有良好的重现性,且形态均一、规整。Objective To compare the features of caps created with small incision lenticule extraction (SMILE) versus flaps created with femtosecond laser-assisted in situ keratomileusis (femto-LASIK).Methods Two hundreds eyes of 100 patients were collected in this study and divided into 2 groups according to the operation methodSMILE group (100 eyes,50 patients) and FS-LASIK group (100 eyes,50 patients).The expected cap or flap thickness was 110 μm for both groups.Fourier-domain optical coherence tomography (RTVue OCT) was used to measure the cap and flap thicknesses of the 7 specified measurements in the 0° and 90° meridians on the corneas,and the thicknesses of 14 measurements on the caps and flaps were compared.Results At one week postoperatively,the central cap thickness of SMILE group [(109.4±2.8)μm] was thinner than central flap thickness of the FS-LASIK group[(111.2±3.6)μm]( t =-3.062, P 〈0.01).The mean whole cap thickness was(109.3±2.1)μm in the SMILE group,which was significant lower than the whole flap thickness in the FS-LASIK group[(111.1±1.8)μm]( t =-5.130, P 〈0.01).The caps and flaps morphology showed uniformity in both groups.There was no significant difference in the mean cap and flap thickness between 0° and 90° meridians (all P 〉0.05).The amount of measurement points differ less than 5 μm was 1170 (83.57%) in the SMILE group,1226 (87.57%) in the FS-LASIK group.Conclusion The corneal caps made by SMILE and the corneal flaps made by FS-LASIK both have good reproducibility,and the shape is uniform and regular.

关 键 词:小切口基质内透镜取出术 Visumax飞秒激光LASIK 近视 角膜瓣 

分 类 号:R779.6[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象