摘  要:为了提高地铁车站站厅层公共区的排烟效率,针对郑州某地铁车站站厅层公共区设计了不同的排烟工况。通过利用FDS模拟软件对不同的排烟工况进行仿真模拟,得到下排烟口、侧排烟口、顶排烟口3种工况下温度、能见度、CO浓度随时间的变化图,通过对比分析得出结论:侧排烟口、顶排烟口、顶排风口均能满足人员的安全疏散要求;侧排烟口、顶排烟口比下排烟口的排烟效果好,侧排烟口和顶排烟口的排烟效果基本相同。通过进一步比较侧排烟口个数及大小对人员安全疏散的影响,得出:6个侧排烟口、3个侧排烟口比12个侧排烟口的排烟效果好;6个侧排烟口与3个侧排烟口的排烟效果基本相同。In order to improve the efficiency of smoke exhaust in the public area of the subway station hall, this paper designs different smoke exhausting conditions for the public area of a subway station in Zhengzhou. Based on FDS software simulation of smoke under different conditions, we get the variation diagram of temperature, visibility and CO concentration with time from the lower smoke outlets, side smoke outlets and top smoke outlets. Comparison and analysis conclude that the side smoke outlets, the top smoke outlets and the top exhaust outlets can meet the safe evacuation requirements of the personnel; the smoke exhaust effects of the side smoke outlets and the top smoke outlets are better than that of the lower smoke outlets, and the smoke exhaust effects of the side smoke outlets and the top smoke outlets are basically the same. By further comparing the influence of the number and the size of side smoke outlets on evacuation, it is concluded that: 6 side smoke outlets and 3 side smoke outlets have better smoke exhaust effect than that of 12 side outlets; the smoke exhaust effect of 6 side smoke outlets and 3 side outlets is basically the same

关 键 词:地铁 站厅火灾 仿真模拟 排烟模式 排烟效果 FDS 

分 类 号:U231.96[交通运输工程—道路与铁道工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象