小梁切除术后青光眼的各项解剖及功能评价指标无变化  

No changes in anatomical and functional glaucoma evaluation after trabeculectomy

在线阅读下载全文

作  者:Tavares I.M. Melo Jr.L.A.S. Prata Jr.J.A. 刘瑛 

机构地区:[1]Department of Ophthalmology,Federal University of So Paulo,Rua Botucatu 822,So Paulo 04023-062,Brazil

出  处:《世界核心医学期刊文摘(眼科学分册)》2006年第10期35-36,共2页Digest of the World Core Medical Journals:Ophthalmology

摘  要:Purpose:To assess the influence of glaucoma filtration surgery on anatomical and functional tests for glaucoma evaluation.Methods:Twenty-five eyes(25 patients)with primary openangle glaucoma were evaluated,prospectively.Data were collected on vision acuity,intraocular pressure,standard automated perimetry,frequency doubling technology perimetry,scanning laser polarimetry(GDx)and confocal scanning laser ophthalmoscopy(HRT II)before and 3-6 months after surgery.Results:Mean(± SD)pre-and postoperative visual acuities(logMAR)were 0.28(± 0.18)and 0.30(± 0.17),respectively(P=0.346).In a mean time of 4.5(± 1.1)months after surgery,the mean preoperative intraocular pressure of 20.7(± 5.4)mmHg decreased to 11.04(± 2.52)mmHg(P < 0.001).The results of the standard automated perimetry,frequency doubling technology perimetry,scanning laser polarimetry and confocal scanning laser ophthalmoscopy diagnostic methods revealed no significant difference(P > 0.162)between pre and postoperative values and no significant correlation(P > 0.296)between intraocular pressure reduction and value changes.Conclusion:No significant change on any test variable was detected after glaucoma filtration surgery.Trabeculectomy does not appear to influence standard automated perimetry,frequency doubling technology perimetry,scanning laser polarimetry and confocal scanning laser ophthalmoscopy(HRT II)results after a 4.5-month period of surgery in early to moderate glaucoma.Purpose:To assess the influence of glaucoma filtration surgery on anatomical and functional tests for glaucoma evaluation.Methods:Twenty-five eyes(25 patients)with primary openangle glaucoma were evaluated,prospectively.Data were collected on vision acuity,intraocular pressure,standard automated perimetry,frequency doubling technology perimetry,scanning laser polarimetry(GDx)and confocal scanning laser ophthalmoscopy(HRT II)before and 3-6 months after surgery.Results:Mean(± SD)pre-and postoperative visual acuities(logMAR)were 0.28(± 0.18)and 0.30(± 0.17),respectively(P=0.346).In a mean time of 4.5(± 1.1)months after surgery,the mean preoperative intraocular pressure of 20.7(± 5.4)mmHg decreased to 11.04(± 2.52)mmHg(P < 0.001).The results of the standard automated perimetry,frequency doubling technology perimetry,scanning laser polarimetry and confocal scanning laser ophthalmoscopy diagnostic methods revealed no significant difference(P > 0.162)between pre and postoperative values and no significant correlation(P > 0.296)between intraocular pressure reduction and value changes.Conclusion:No significant change on any test variable was detected after glaucoma filtration surgery.Trabeculectomy does not appear to influence standard automated perimetry,frequency doubling technology perimetry,scanning laser polarimetry and confocal scanning laser ophthalmoscopy(HRT II)results after a 4.5-month period of surgery in early to moderate glaucoma.

关 键 词:小梁切除术 功能评价指标 倍频视野计 自动视野计 平均眼压 滤过术 平均视力 功能检查结果 主要检测 

分 类 号:R779.6[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象