摘  要:A high-performance liquid chromatography coupled with mass spectrometry(HPLC–MS) method was established for the separation and determination of acetyl-glutamine enantiomers(acetylL-glutamine and acetylD-glutamine) simultaneously. Baseline separation was achieved on Chiralpak AD-H column(250 mm ×4.6 mm, 5 μm). n-Hexane(containing 0.1% acetic acid) and ethanol(75:25, v/v) were used as mobile phase at a flow rate of 0.6 m L/min. The detection was operated in the negative ion mode with an ESI source. [M-H]-m/z187.0540 for enantiomers and [M-H]-m/z 179.0240 for aspirin(IS) were selected as detecting ions. The linear range of the calibration curve for each enantiomer was 0.05–40 μg/m L. The precision of this method at concentrations of 0.5–20 μg/m L was within 7.23%, and the accuracy was 99.81%–107.81%. The precision at LOQ(0.05 μg/m L) was between 16.28% and 17.56%, which was poor than that at QC levels. The average extraction recovery was higher than 85% for both enantiomers at QC levels. The pharmacokinetics of enantiomers was found to be stereoselective. There was not chiral inversion in vivo or in vitro between enantiomers.A high-performance liquid chromatography coupled with mass spectrometry(HPLC–MS) method was established for the separation and determination of acetyl-glutamine enantiomers(acetylL-glutamine and acetylD-glutamine) simultaneously. Baseline separation was achieved on Chiralpak AD-H column(250 mm ×4.6 mm, 5 μm). n-Hexane(containing 0.1% acetic acid) and ethanol(75:25, v/v) were used as mobile phase at a flow rate of 0.6 m L/min. The detection was operated in the negative ion mode with an ESI source. [M-H]-m/z187.0540 for enantiomers and [M-H]-m/z 179.0240 for aspirin(IS) were selected as detecting ions. The linear range of the calibration curve for each enantiomer was 0.05–40 μg/m L. The precision of this method at concentrations of 0.5–20 μg/m L was within 7.23%, and the accuracy was 99.81%–107.81%. The precision at LOQ(0.05 μg/m L) was between 16.28% and 17.56%, which was poor than that at QC levels. The average extraction recovery was higher than 85% for both enantiomers at QC levels. The pharmacokinetics of enantiomers was found to be stereoselective. There was not chiral inversion in vivo or in vitro between enantiomers.

关 键 词:HPLC–MS Acetyl-glutamine ENANTIOMERS SEPARATION Pharmacokinetics Chiral inversion 

分 类 号:R96[医药卫生—药理学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象