检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:孙权[1] 王友仁[1] 姜媛媛[1,2] 邵力为 Sun Quan;Wang Youren;Jiang Yuanyuan;Shao Liwei(College of Automation Nanjing University of Aeronautics and Astronautics Nanjing 211106 China;College of Electrical and Information Engineering Anhui University of Science and Technology Huainan 232001 China)
机构地区:[1]南京航空航天大学自动化学院,南京211106 [2]安徽理工大学电气与信息工程学院,淮南232001
出 处:《电工技术学报》2018年第6期1364-1373,共10页Transactions of China Electrotechnical Society
基 金:国家自然科学基金(61371041);江苏省普通高校研究生科研创新计划资助项目;中央高校基本科研业务费专项资金(KYLX_0250);航空科学基金(2013ZD52055);国家商用飞机制造工程技术研究中心创新基金(SAMC14-JS-15-051)资助项目
摘 要:基于特征参数估计的关键元器件健康状态评估是实现电路级故障预测与健康管理的关键技术。然而,工作温度的变化会导致元器件特征参数估计值与失效标准(25℃条件下)不统一,致使状态评估结果不准确。针对该关键问题,以非理想Boost变换器为例,首先,采用改进粒子群优化算法辨识关键元器件特征参数值;然后,分别建立电解电容、功率MOSFET器件特征参数与工作温度的数学模型,并定义器件特征参数归一化因子(NF)及健康指标(HI);最后,提出基于无迹粒子滤波(UPF)动态更新模型参数的方法估计归一化后的特征参数值,从而实现变温度下关键元器件健康状态评估。搭建硬件实验平台,通过研究结果表明参数辨识误差小于5%,健康评估准确度可达90%以上,验证了所提方法的有效性。The health condition assessment for key components based on characteristic parameter estimation is one of the most significant technologies for circuit-level prognostics and health management(PHM).However,changes in operating temperature can lead to inconsistencies in the estimated values of characteristic parameters and their failure criteria(at 25 degrees Celsius),resulting in inaccurate condition evaluation.Therefore,for the non-ideal Boost converter,firstly,this paper provides the values of characteristic parameters by particle swarm optimization(PSO)algorithm.Then,the mathematical models of the characteristic parameters and operating temperature for electrolytic capacitor and power MOSFET are established,respectively.Meanwhile,the normalized factor(NF)and health index(HI)are defined in this paper.Finally,to achieve health condition assessment under various temperature conditions,a novel approach of updating the model parameters dynamically based on unscented particle filter is proposed.In addition,experimental results show that the parameter identification error is less than 5%and the health evaluation accuracy is over 90%.
关 键 词:BOOST变换器 状态监测 特征参数 参数辨识 健康状态评估
分 类 号:TM46[电气工程—电器] TP206.3[自动化与计算机技术—检测技术与自动化装置]