检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:冯小丽 李明华[1,2] 韩建保 王洪波[3] 郑永唐 FENG Xiao-li;LI Ming-hua;HAN Jian-bao;WANG Hong-bo;ZHENG Yong-tang(Biosafety Level-3 Laboratory of Kunming Institute of Zoology, Chinese Academic of Sciences, Kunming 650223, China;Key Laboratory of Animal Models and Human Disease Mechanisms of Chinese Academy of Sciences&Yunnan Province;The National Kunming High Level Biosafety Research Center For Non-human Primate;Shenzhen Biovano Technology Co.,Ltd,Shenzhen 518053,China)
机构地区:[1]中国科学院昆明动物研究所生物安全三级实验室,昆明650223 [2]国家昆明高等级生物安全灵长类动物实验中心,昆明650107 [3]深圳柏安诺科技有限公司,518053 [4]中国科学院动物模型与人类疾病机理重点实验室
出 处:《中国医药生物技术》2018年第2期123-127,共5页Chinese Medicinal Biotechnology
基 金:中国科学院重点部署项目课题(ZDRW-ZS-2016-4-2)
摘 要:目的观察两种过氧化氢蒸汽发生器分别对生物安全三级实验室的房间及传递窗的空间和内表面的灭菌效果。方法采用载体定性杀菌试验方法,检测不同浓度的过氧化氢空间分布量对密闭房间和传递窗的熏蒸消毒灭菌效果,同时还检测了同一浓度的过氧化氢空间分布量对不同体积密闭房间的熏蒸消毒灭菌效果。结果用BIOQUELL Z-2型过氧化氢蒸汽发生器对房间进行灭菌验证,当过氧化氢空间分布量达到10 g/m^3时可以将放置在房间内不同位置的嗜热脂肪芽孢杆菌载体完全杀灭;采用10 g/m^3的过氧化氢空间分布量对5个不同体积的房间进行灭菌验证,均可以达到灭菌效果。用BIOQUELL L-2型过氧化氢蒸汽发生器对传递窗进行灭菌验证,用25 g过氧化氢可以将放置在传递窗内不同位置的嗜热脂肪芽孢杆菌载体完全杀灭。结论 BIOQUELL Z-2和BIOQUELL L-2型过氧化氢蒸汽发生器均可用于生物安全三级实验室房间和传递窗的消毒灭菌,灭菌效果符合要求。Objective To observe the sterilization efficacy of two hydrogen peroxide vapor generators in indoor air and surface of biosafety level-3 laboratory and pass-through box.Methods A carrier qualitative germicidal test method was applied to observe the sterilization efficacy of different hydrogen peroxide dosage in space and on the surface of the enclosed room and pass-through box,and the sterilization efficacy of the selected hydrogen peroxide dosage in space and on surface of the enclosed rooms with various volume was also detected.Results When hydrogen peroxide vapor reached 10 g/m3,all the carriers of Bacillus stearothermophilus put in different places of the enclosed room were killed completely by BIOQUELL Z-2 hydrogen peroxide vapor generator,and the carriers of Bacillus stearothermophilus put in the 5 enclosed rooms with different volumes were all killed too.Furthermore,the carriers of Bacillus stearothermophilus put in different places of the pass-through box were completely killed when hydrogen peroxide vapor was 25 g using BIOQUELL L-2 hydrogen peroxide vapor generator.Conclusion BIOQUELL Z-2 and BIOQUELL L-2 hydrogen peroxide vapor generators could be used in the biosafety level-3 laboratory for the sterilization of the enclosed rooms and pass-through box.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.3