不同临床经验医师应用LOCSⅢ对晶状体混浊程度评分的一致性研究  被引量:6

Repeatability of Lens Opacity Classification System Ⅲ between physicians with different clinical experience

在线阅读下载全文

作  者:乔利亚 李晓霞 顾铮[3] 简泠雪 张烨 蔡啸谷 管征 李思珍 QIAO Li-Ya;LI Xiao-Xia;GU Zheng;Catherine Jan;ZHANG Ye;CAI Xiao-Gu;GUAN Zheng;LI Si-Zhen(the Beijing Tongren Eye Center,Beijing Tongren Hospital,Capital Medical University,Beijing Ophthalmology and Visual Sciences Key Laboratory,Beijing 100730,China;Beijing Tongren Eye Center,Beijing Tongren Hospital,Capital Medical University,Beijing Ophthalmology and Visual Sciences Key Laboratory,Beijing institute of Ophthalmology,Beijing 100730,China;Department of Ophthalmology,Beijing Anzhen Hospital,Capital Medical University,Beijing 100029,China;School of Psychological and Cognitive Sciences,Beijing 100871,China;Department of Ophthalmology,Nanjing Tongren Hospital,Nanjing 210000,Jiangsu Province,China)

机构地区:[1]首都医科大学附属北京同仁医院北京同仁眼科中心,北京市眼科学与视觉科学重点实验室,北京市100730 [2]首都医科大学附属北京同仁医院北京同仁眼科中心,北京市眼科学与视觉科学重点实验室,北京市眼科研究所,北京市100730 [3]首都医科大学附属北京安贞医院眼科,北京市100027 [4]北京大学心理与认知科学学院,北京市100871 [5]东南大学医学院附属南京同仁医院眼科,江苏省南京市210000

出  处:《眼科新进展》2018年第7期669-672,共4页Recent Advances in Ophthalmology

摘  要:目的评价不同临床经验医师应用晶状体混浊分级系统(Lens Opacity Classification System Ⅲ,LOCSⅢ),基于裂隙灯及数码照片进行晶状体混浊程度评分的一致性。方法从邯郸眼病研究5 a随访项目中,随机选取2012年11月至2012年12月现场调查受试者51人(102眼)。首先由受过LOCSⅢ评分培训的高年资眼科副主任医师(评分员A)于现场参照LOCSⅢ标准图片,在裂隙灯下对晶状体核混浊程度(nuclear opacity,NO)、核颜色(nuclear color,NC)、皮质性白内障(cortical cataract,C)、后囊膜下白内障(posterior subcapsular cataract,PSC)进行评分,随后采集晶状体数码照片。评分员A和1名眼科住院医师(评分员B)根据晶状体数码照片独立进行NO、NC、C、PSC评分。然后一位经过LOCSⅢ晶状体评分培训的白内障专业副主任医生对评分员B进行培训,同时与评分员A进行讨论并统一对LOCSⅢ标准评分方法的理解后,评分员B进行第2次评分。均采用组内相关系数(intraclass correlation coefficient,ICC)分别检验评分员A基于裂隙灯及数码照片的LOCSⅢ晶状体评分的一致性,评分员B培训前、后的LOCSⅢ晶状体评分的一致性,以及评分员B培训前、后的LOCSⅢ晶状体评分与评分员A基于裂隙灯及数码照片的LOCSⅢ晶状体评分进行一致性检验。结果评分员A基于现场裂隙灯和晶状体数码照片的LOCSⅢ晶状体评分的ICC分别为:NO 0.89、NC 0.89、C 0.90、PSC0.65;评分员B培训前、后LOCSⅢ晶状体评分ICC分别为:NO 0.90、NC 0.90、C 0.89、PSC 0.12;评分员B培训前、后基于数码照片与评分员A基于裂隙灯的LOCSⅢ晶状体评分ICC分别为NO 0.77、0.82,NC 0.79、0.85,C 0.77、0.89,PSC 0.05、0.46;评分员B培训前、后与评分员A基于数码照片的LOCSⅢ晶状体评分比较ICC分别为:NO 0.83、0.81,NC 0.80、0.84,C 0.76、0.88,PSC 0.26、0.85。结论眼科临床经验对临床医师采用LOCSⅢ进行NO、NC、C评分影响不大,对PSC评分影响�Objective To evaluate the repeatability of Lens Opacity Classification SystemⅢ(LOCSⅢ)based on slit lamp and digital photos,as well as between different clinical physicians.Methods From November 2012 to December 2012,51 participants(102 eyes)were randomly selected from the five year follow-up study of Handan eye study.Firstly,a senior ophthalmologist(scorer A)graded lens nuclear opacities(NO),nuclear color(NC),cortical cataract(C)and posterior capsular cataract(PSC)under slit lamp on the scene,referring to the LOCSⅢstandard pictures.Then the lens digital photos were collected.The scorer A and one intern(scorer B)independently performed NO,NC,C and PSC scores according to the lens digital photographs.Then a cataract professional ophthalmologist,who was trained by the LOCSⅢlens score training,trained the scorer B.After scorer A and B discussed and unified the LOCSⅢstandard scoring method,scorer B scored the lens digital photographs for the second time.Repeatability of the LOCSⅢscore of the scorer A based on slit lamp and digital photograph was evaluated.Repeatability of the LOCSⅢscore of the scorer B before and after training was evaluated.The LOCSⅢscore of the scorer B before and after training was also compared to the LOCSⅢscore of the scorer A based on slit lamp and digital photos.Results Intraclass correlation coefficients(ICC)for the LOCSⅢscore of the scorer A based on digital photos and digital photos was 0.89 for NO and NC,0.90 for C and 0.65 for PSC.Intraclass correlation coefficients(ICC)for the LOCSⅢscore of the scorer B before and after training was 0.90 for NO and NC,0.89 for C and 0.12 for PSC.Intraclass correlation coefficients(ICC)for the LOCSⅢscore of the scorer B before training and the LOCSⅢscore of the scorer A based on slit lamp was 0.77 for NO,0.79 for NC,0.77 for C and 0.05 for PSC.After training,the ICC was 0.82 for NO,0.85 for NC,0.89 for C and 0.46 for PSC.Intraclass correlation coefficients(ICC)for the LOCSⅢscore of the scorer B after training and the LOCSⅢscor

关 键 词:裂隙灯 数码照片 LOCSⅢ晶状体评分 一致性 