Screw placement is everything: Risk factors for loss of reduction with volar locking distal radius plates  被引量:1

Screw placement is everything: Risk factors for loss of reduction with volar locking distal radius plates

在线阅读下载全文

作  者:Herwig Drobetz Alyce Black Jonathan Davies Petra Buttner Clare Heal 

机构地区:[1]James Cook University School of Medicine and Dentistry [2]Mackay Institute of Research and Innovation, Mackay Hospital [3]Mackay Base Hospital Orthopaedic Department, Mackay Hospital [4]Tropical Health Solutions PTY Ltd [5]Centre for Chronic Disease Prevention, James Cook University [6]Anton Breinl Research Centre for Health Systems Strengthening

出  处:《World Journal of Orthopedics》2018年第10期203-209,共7页世界骨科杂志(英文版)

摘  要:AIM To determine factors correlated with postoperative radial shortening in patients with distal radius fractures treated with volar locking distal radius plates.METHODS A total of 250 patients with a distal radius fracture stabilised with volar locking plates between January 2010 and December 2014 were included in a multicentre retrospective cohort study. We measured the distance of the distal locking screws to the joint line immediately postoperatively and then measured radial shortening after six to eight weeks using the change in ulnar variance.RESULTS Multivariate linear regression analysis showed that there was a significant linear association between the distance of the screws from the joint line and radial shortening. No other patient, injury, or treatment-related characteristic significantly influenced radial shortening in multivariate analysis.CONCLUSION Distal locking screws should be placed as close as possible to the subchondral joint line to prevent postoperative loss of reduction.AIM To determine factors correlated with postoperative radial shortening in patients with distal radius fractures treated with volar locking distal radius plates.METHODS A total of 250 patients with a distal radius fracture stabilised with volar locking plates between January 2010 and December 2014 were included in a multicentre retrospective cohort study. We measured the distance of the distal locking screws to the joint line immediately postoperatively and then measured radial shortening after six to eight weeks using the change in ulnar variance.RESULTS Multivariate linear regression analysis showed that there was a significant linear association between the distance of the screws from the joint line and radial shortening. No other patient, injury, or treatment-related characteristic significantly influenced radial shortening in multivariate analysis.CONCLUSION Distal locking screws should be placed as close as possible to the subchondral joint line to prevent postoperative loss of reduction.

关 键 词:LOSS of REDUCTION VOLAR LOCKING DISTAL RADIUS plate DISTAL RADIUS fracture Screw placement Cohort study 

分 类 号:R[医药卫生]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象