高度近视白内障患者植入三焦点人工晶体的临床效果及生存质量观察  被引量:7

Postoperative visual performance and life quality of cataract patients with high myopia with implantation of multifocal intraocular lens

在线阅读下载全文

作  者:谢瞻[1] 丁宇华[1] 陈雪[1] 刘庆淮[1] 顾刘伟[1] 王飞[1] Xie Zhan;Ding Yuha;Chen Xue;Liu Qinhuai;Gu Liuwei;Wang Fei(Department of Ophthalmology,the First Affiliated Hospital of NMU,Nanjing 210029,China)

机构地区:[1]南京医科大学第一附属医院眼科,江苏南京210029

出  处:《南京医科大学学报(自然科学版)》2019年第3期365-369,共5页Journal of Nanjing Medical University(Natural Sciences)

基  金:国家自然科学基金(81700877)

摘  要:目的:观察并比较AT LISA tri 839MP三焦点人工晶体及CT SPHERIS 209M单焦点人工晶体植入术后高度近视患者的视力、对比敏感度和视觉质量。方法:行白内障超声乳化摘除联合人工晶体植入术的患者44例(44眼),其中三焦组22例(22眼),术中植入AT LISA tri 839MP三焦点人工晶体,单焦组22例(22眼),术中植入CT SPHERIS 209M单焦点人工晶体。术后3个月检查患者的裸眼远距离视力(uncorrected distance visual acuity,UCDVA)、裸眼中距离视力(uncorrected intermediate vi-sual acuity,UCIVA)、裸眼近距离视力(uncorrected near visualacuity,UCNVA)、最佳矫正远视力(best corrected distance visual acuity,BCDVA)、远视力矫正下的中距离视力(distance corrected intermediate visual acuity,DCIVA)、远视力矫正下的近距离视力(distance corrected near visual acuity,DCNVA),明、暗环境中不同空间频率(3、6、12、18 cpd)下的对比敏感度,并进行脱镜率、不良视觉症状和满意度等问卷调查。采用SPSS16.0统计软件对结果进行统计分析。结果:术后3个月三焦组UCIVA、UCN-VA、DCIVA和DCNVA、脱镜率及满意度优于单焦组(P均<0.05)。在明、暗环境中的18 cpd空间频率,单焦组的对比敏感度优于三焦组(P均<0.05)。两组均有轻度眩光和光晕不适主诉,组间差异无统计学意义(P=0.50)。结论:与CT SPHERIS 209M单焦点人工晶状体比较,AT LISA tri 839MP三焦点人工晶体为高度近视患者提供了更好的中、近视力,脱镜率和满意度均高于单焦点人工晶体。Objective:To compare the visual acuity,contrast sensitivity and visual quality of patients with high myopia after the implantation of AT LISA tri 839 MP multifocal intraocular lens and CT SPHERIS 209 M monofocal intraocular 1 ens. Methods:Forty-four patients(44 eyes)were involved and divided into two groups in this study. The trail group(22 patients,22 eyes)received AT LISA tri 839 MP multifocal intraocular lens implantation and the control group(22 patients,22 eyes)received CT SPHERIS 209 M monofocal intraocular lens implantation after phacoemulsification. Parameters including visual acuity,contrast sensitivity at different spatial frequencies(3,6,12,18 cpd)in bright and dark circumstances,independent spectacles ratio,satisfaction and photic phenomena were observed. The post-operative visual acuity included the information of uncorrected distance visual acuity(UCDVA),uncorrected intermediate visual acuity(UCIVA),uncorrected near visual acuity(UCNVA),best corrected distance visual acuity(BCDVA),distance corrected intermediate visual acuity(DCIVA),and distance corrected near visual acuity(DCNVA). The SPSS 16.0 statistic software was used to analyze the data. Results:The UCIVA,UCNVA,DCIVA,DCNVA,independent spectacles ratio and satisfaction of the trail group were better than those of the control group(all P < 0.05). The mean contrast sensitivity at spatial frequency of 18 cpd in bright and dark circumstances of the control group was higher than that of the control group(P < 0.05). The incidence of glare and halo showed no significantly statistical difference between two groups(P=0.50). Conclusion:AT LISA tri 839 MP multifocal intraocular lens provided better intermediate and near vision,higher independent spectacles ratio and more satisfaction of patients than CT SPHERIS209 M monofocal intraocular lens.

关 键 词:高度近视 白内障 三焦点人工晶体 视力 对比敏感度 视觉质量 

分 类 号:R776.1[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象