作 者:张静 刘治容[2] 张瑞帆[2] 陈波[2] 陈斌[2] 吴峥峥[2] Jing Zhang;Zhi-Rong Liu;Rui-Fan Zhang;Bo Chen;Bin Chen;Zheng-Zheng Wu(Shenzhen Eye Hospital, Shenzhen Key Laboratory of Ophthalmology, Affiliated Shenzhen Eye Hospital of Jinan University, Shenzhen 518040, Guangdong Province, China;Department of Ophthalmology, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Chengdu 610072, Sichuan Province, China)
机构地区:[1]中国广东省深圳市眼科医院,深圳眼科学重点实验室,暨南大学附属深圳眼科医院,518040 [2]四川省医学科学院·四川省人民医院眼科,四川省成都610072
出 处:《国际眼科杂志》2019年第6期1012-1016,共5页International Eye Science
摘 要:目的:采用视觉质量分析系统(OQAS)评价不同近视患者行飞秒激光制瓣准分子激光原位角膜磨镶术(FS-LASIK)后视觉质量的变化。方法:共收集行FS-LASIK的患者65例130眼,分为低、中、高度近视三组。采用OQAS系统检查比较三组患者术前术后视觉质量参数的变化。结果:低度近视组术后10dOV100%、MTFcutoff值高于高度近视组,OV20%、OV9%值高于中、高度近视组(均P<0.017)。术后1d低度近视组和术后1、10、30d中、高度近视组OSI和MeanOSI均比术前显著升高,而MTFcutoff、SR、OV100%、OV20%、OV9%均比术前显著降低(均P<0.0083)。MeanOSI与OV100%、OV20%、OV9%、SR、MTFcutoff均呈负相关,与OSI均呈正相关(均P<0.05)。结论:FS-LASIK术后早期视觉质量下降,泪膜功能与视觉质量变化趋势一致,低度近视比中、高度近视患者恢复更快。AIM: To evaluate the effects of femtosecond laser in situ keratomileusis (FS-LASIK) on visual quality of myopia with different refractive degrees using the Optical Quality Analysis System (OQAS). METHODS: A total of 65 myopic patients (130 eyes) who received FS-LASIK were collected, which were divided into three groups of low, medium and high myopia. The changes of visual quality parameters before and after surgery were compared by OQAS system. RESULTS:The values of OV100% and MTF cutoff in the low myopia group at 10d after surgery were higher than those in the high myopia group, and the values of OV20% and OV9% were higher than those in the medium and high myopia group (all P <0.017). At 1d after surgery in low myopia group and at 1d, 10d and 30d after surgery in medium and high myopia group had significantly higher OSI and Mean OSI, while MTF cutoff, SR, OV100%, OV20% and OV9% were significantly lower than those before surgery (all P <0.0083). Mean OSI was negatively correlated with OV100%, OV20%, OV9%, SR, MTF cutoff and positively correlated with OSI (all P <0.05). CONCLUSION:Optical quality decreases in the early period after FS-LASIK for correction of distinct refractive errors, and the visual quality recovery after the operation of low myopia is faster than that of medium and high myopia. The changes of tear film function and visual quality after FS-LASIK were consistent.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.17.191.196