化学发光法定量检测抗ENA抗体和抗dsDNA抗体临床性能评价  被引量:2

Clinical performance evaluation to chemiluminescence immunoassay for the detection of anti-ENA and anti-dsDNA

在线阅读下载全文

作  者:柳晓琴[1,2] 崔亚利 沈川[1] 甘春玉[1] 段义飞[1] 彭磊文[1] 李文胜[1] LIU Xiaoqin;CUI Yali;SHEN Chuan;GAN Chunyu;DUAN Yifei;PENG Leiwen;LI Wensheng(Department of Clinical Laboratory,West China Second University Hospital of Sichuan University,Chengdu,Sichuan 610041,China;Key Laboratory of Birth Defects and Related Diseases of Women and Children (Sichuan University),Ministry of Education,Chengdu,Sichuan 610041,China)

机构地区:[1]四川大学华西第二医院临床检验科,四川成都610041 [2]出生缺陷与相关妇儿疾病教育部重点实验室,四川成都610041

出  处:《国际检验医学杂志》2019年第12期1475-1479,1485,共6页International Journal of Laboratory Medicine

摘  要:目的分析SMART-6500化学发光检测平台针对抗可提取物核抗原抗体(抗ENA抗体)及抗双链DNA抗体(抗dsDNA抗体)的定量检测性能。方法参照美国临床和实验室标准化协会(CLSI)EP系列文件的要求,分析SMART-6500化学发光检测平台检测抗ENA抗体和抗dsDNA抗体的精密度、线性范围、生物参考区间和方法学对比等性能指标。应用世界卫生组织(WHO)标准物质(NIBCS代码:15/174)对抗dsDNA抗体检测项目开展量值溯源研究。结果抗ENA抗体和抗dsDNA抗体的批内精密度变异系数(CV)和批间精密度CV分别处于2.16%~6.67%和4.70%~12.71%;线性范围R值处于0.9926~0.9980;方法学对比显示所有检测项目的总符合率均大于90%。抗dsDNA抗体国际标准物质经SMART-6500检测结果为24.67U/mL。结论SMART-6500化学发光检测平台在检测抗ENA抗体和抗dsDNA抗体时,表现出良好的精密度和线性范围,与酶联免疫吸附试验的检测结果具有较高的符合率,因此可满足免疫临床对于抗ENA抗体和抗dsDNA抗体定量检测的需要。Objective To evaluate the feature of quantitative measurement to anti-ENA antibody and anti-dsDNA with SMART-6500 chemiluminescence immunoassay. Methods According to the requirements of Clinical and Laboratory Standards Institute (CLSI) EP series documents,the performance indicators of SMART-6500 Chemiluminescence Detection Platform for detecting anti-ENA and anti-dsDNA,such as precision,linear range,biological reference range and methodological comparison,were analyzed.The quantitative traceability of anti dsDNA detection project was studied by using World Health Organization (WHO) reference material (NIBCS code:15/174). Results The coefficient variation (CV) for each assay from the precision study ranged from 2.16% to 6.67%(within-run) and from 4.70% to 12.71%(intra-day),respectively.The linearity analysis showed linearity regression value within 0.992 6-0.998 0 for each assay.Methodological comparison showed that the total coincidence rate of all test items was more than 90%.Anti-dsDNA international standard substance was detected by SMART-6500 was 24.67 U/mL. Conclusion SMART-6500 Chemiluminescence Detection Platform shows good precision and linearity in detecting anti-ENA and anti-dsDNA,and has a high coincidence rate with enzyme linked immunosorbent assay detection results,so it can meet the needs of immunology clinic for quantitative detection of anti-ENA and anti-dsDNA.

关 键 词:SMART-6500 化学发光 抗ENA抗体 抗DSDNA抗体 定量检测 性能评价 

分 类 号:R-331[医药卫生]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象