低频强声驱散样机对静音室内实验动物的损伤效应观察  被引量:1

Damaging Effect of Low-frequency Strong Sound Disperser on Experimental Animals in Silent Room

在线阅读下载全文

作  者:段朝霞 李冠桦 张东冬 翁昌梅 陈魁君 张洁元 张良潮 陈志强 谢秀娟[2] 王建民 DUAN Zhao-xia;LI Guan-hua;ZHANG Dong-dong;WENG Chang-mei;CHEN Kui-jun;ZHANG Jie-yuan;ZHANG Liang-chao;CHEN Zhi-qiang;XIE Xiu-juan;Wang Jian-min(Department Weapon Bioeffect Assessment of Research Institute of Surgey,Daping Hospital,Army Medical University,State key laboratory of Trauma,Burns and Combined Injury,Chongqing 400042,China;Technical Institute of Physics and Chemistry,Chinese Academy of Sciences,Beijing 100190,China)

机构地区:[1]陆军军医大学大坪医院武器杀伤生物效应评估研究室,创伤、烧伤、复合伤国家重点实验室,重庆400042 [2]中国科学院理化技术研究所,北京100190

出  处:《解放军医药杂志》2020年第1期11-15,共5页Medical & Pharmaceutical Journal of Chinese People’s Liberation Army

基  金:国家重点研发计划(2016YFC0800306)

摘  要:目的 为了解低频强声驱散样机(75~85Hz)在不同声强(108~141.5dB)情况下的安全性和有效性,以及低频强声对不同实验动物损伤效应特点,为低频强声驱散样机的定型与使用安全,也为制定该类伤员的诊断、救治、防护措施提供依据。方法 通过用不同声强1(08~141.5dB)作用于放于静音室的不同类实验动物(山羊6只、巴马小香猪4只和SD大鼠40 只3)0min。采用大体与病理解剖、心电、听觉脑干诱发电位、行为学等手段评估不同声强的低频驱散样机在静音室内对实验动物的生物损伤效应。结果 不同强度的低频强声作用于放于静音室内的实验动物30 min后,最高声强1(41.5dB)作用后可引起部分动物脏器(心、肺、肝)的点状出血(轻微损伤),但未发现听阈、功能及行为学异常;≤130dB声强作用后均未发现动物听阈、解剖、功能及行为学异常。结论 该低频强声驱散样机在声强141.5dB时可引起部分大动物(山羊和巴马小香猪)的轻微损伤;低频强声主要引起大动物的内脏损伤,对听觉器官损伤不明显;该低频强声驱散样机在现有频率和强度下仅会引起实验动物主要脏器的点状出血,无不可逆性损伤,具有安全性且具有潜在的驱散能力。Objective In order to learn safety and effectiveness of low-frequency strong sound disperser(75Hz-85Hz)in different sound intensity(108dB-141.5dB),as well as characteristics of damaging effect on experimental animals so as to provide basis for typing and use safety of low-frequency strong sound disperser and diagnosis,treatment and protective measure for these kind of wounded soldiers.Methods Different types of experimental animals(6 goats,4 Bama miniature pigs and 40 rats)were placed in silent room in different sound intensities(108dB-141.5dB)for 30 min.Biological damage effects of low-frequency dispersers with different sound intensities on experimental animals in silent room were evaluated by means such as gross and pathological anatomy,electroencephalogram,auditory brainstem response(ABR)and behavioral techniques.Results After low-frequency strong sounds of different intensities acted on experimental animals placed in silent room for 30 min,and the highest sound intensity(141.5dB)could cause punctate hemorrhage of some animal organs(heart,lung and liver,slight damaging),but hearing threshold,function and behavioral abnormalities did not be found;no hearing threshold,anatomy,function and behavioral abnormalities were found in sound intensity less than 130dB.Conclusion Low-frequency strong sound disperser in 141.5dB sound intensity may cause slight damaging of some large animals(goats and Bama miniature pigs).Low-frequency strong sounds mainly cause visceral injuries,but they are not obvious in auditory organ injuries of large animals.Low-frequency strong sound disperser with existing frequency and sound intensity may cause punctate hemorrhage of main organs in experimental animals without irreversible damage,and it is safe with potential dissipation ability.

关 键 词:低频强声 丙氨酸转氨酶 血尿素 肌酸激酶 神经元特异性烯醇酶 听力 动物行为学 动物实验 

分 类 号:R-332[医药卫生]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象