The Value of Apparent Diffusion Coefficient in Differential Diagnosis of Ovarian Cystic Adenoid Tumors  

在线阅读下载全文

作  者:Lin Sun Ruirui Xu Wei Yan Meng Zhao Fei Chen 

机构地区:[1]Department of Radiology,Binzhou People’s Hospital,Binzhou,Shandong,256600,China [2]Department of Nephrology,Binzhou People’s Hospital,Binzhou,Shandong,256600,China [3]Department of Pathology,Binzhou People’s Hospital,Binzhou,Shandong,256600,China

出  处:《Proceedings of Anticancer Research》2019年第2期1-6,共6页抗癌研究

摘  要:Objective:To quantitatively analyze apparent diffusion coefficient(ADC)value of cystic composition and solid composition in ovarian cystadenocarcinoma,borderline cystadenoma and cystadenoma by 3.0T magnetic resonance imaging(MRI),and to investigate its diagnostic and differential diagnostic values in ovarian cystic adenoid tumors.Methods:Retrospective analysis was carried out on 28 patients with ovarian cystic adenoid tumor as confirmed by surgical and pathological examinations.Examination was performed by Siemens 3.0T MRI scanner.Tumor size,margin,composition(cystic or solid),signal characteristic and presence of ascites were observed.Combined with localization using T2WI and diffusion weighted imaging(DWI),ADC value was calculated from ADC mapping using region of interest ROI(the largest surface area of cystic and solid compositions in tumor).Statistical analysis was performed.Results:Among the 28 ovarian tumors,there were 13 cases of cystadenomas(5 serous cystadenomas and 9 mucinous cystadenomas),4 borderline mucinous cystadenomas and 11 cystadenocarcinoma(9 serous cystadenocarcinoma and 2 mucinous cystadenocarcinoma).There was no significant intragroup difference in ADC values of cystic composition and solid composition in ovarian cystadenoma and cystadenocarcinoma respectively(P>0.05).The ADC value of solid composition between benign cystadenoma and borderline cystadenoma(P<0.05)showed statistically significantly difference.The difference in ADC value of solid composition between benign cystadenoma and cystadenocarcinoma was also statistically significant(P<0.05).There was no significant difference in ADC value of cystic composition between benign cystadenoma,borderline cystadenoma and cystadenocarcinoma(P>0.05).Conclusion:Quantitative analysis of ADC value of solid composition using 3.0T MRI has great value in differential diagnosis of benign and malignant ovarian cystic adenoid tumors.Its combination with conventional MRI method can improve the accuracy of diagnosis of ovarian cystic adenoid tumors.

关 键 词:Apparent diffusion coefficient Magnetic resonance imaging OVARIAN CYSTADENOMA CYSTADENOCARCINOMA BORDERLINE CYSTADENOMA 

分 类 号:R73[医药卫生—肿瘤]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象