检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:游嘉[1] 刘云峰[1] 潘小波[2] 唐增斌[2] 张建兴[3] 徐旭[4] YOU Jia;LIU Yun-feng;PAN Xiao-bo(Zhejiang University of Technology, Hangzhou 310014, China)
机构地区:[1]浙江工业大学,杭州310014 [2]广西壮族自治区人民医院口腔科,南宁530021 [3]浙江省人民医院口腔科,杭州310014 [4]衢州市人民医院口腔科,浙江324000
出 处:《中国临床新医学》2020年第4期327-331,共5页CHINESE JOURNAL OF NEW CLINICAL MEDICINE
基 金:国家自然科学基金项目(编号:51775506)。
摘 要:目的分析有压板和无压板两种类型的导航工具对数字化种植导板手术备孔精度的影响。方法回顾性分析有压板导航工具和无压板导航工具植入的16例患者,共40颗种植体,每种工具各20颗。术前通过六维牙种植设计软件对种植体位点进行三维设计,术后拍摄CT并在六维牙种植设计软件中进行重建,与术前方案进行配准后导入Rhino软件中,对术前术后种植体颈部中心点距离偏差、底部中心点距离偏差、颈部垂直向偏差和角度偏差进行测量比较。结果有压板导航工具植入的种植体颈部中心点距离偏差均值为1.243 mm,底部中心点距离偏差均值为1.911 mm,颈部垂直向偏差均值为1.201 mm,角度偏差均值为5.077°,无压板导航工具植入的种植体依次为0.696 mm、1.167 mm、0.449 mm、4.582°。结论无压板的导航工具备孔精度高于有压板的导航工具备孔精度。Objective To analyze the effects of two types of surgical guide kits with drilling key and without drilling key on the surgical accuracy of digital guided dental implant surgery.Methods A retrospective analysis was performed on 16 patients with 40 implants of two types of surgical guide kits with drilling key and without drilling key in total,and 20 implants for each type.The three-dimensional(3D)positions of the implants were designed by 6D Dental Planning Software.After the operation,computed tomography(CT)was taken and the implants were reconstructed by the 6D Dental Planning Software.After rectification with the preoperative model,the implants were imported into Rhino software to obtain the distance deviation of implant neck center point,the distance deviation of implant bottom center point,the vertical deviation of neck and the angle deviation before and after the operation,and the preoperative and postoperative deviations were compared.Results In the implants with drilling key,the mean distance deviation of implant neck center point was 1.243 mm;the mean distance deviation of implant bottom center point was 1.911 mm;the mean vertical deviation of neck was 1.201 mm,and the mean angle deviation in angulation was 5.077°.In the implants without drilling key,the mean distance deviation of implant neck center point was 0.696 mm;the mean distance deviation of implant bottom center point was 1.167 mm;the mean vertical deviation of neck was 0.449 mm,and the mean angle deviation in angulation was 4.582°.Conclusion The accuracy of guided implant surgery operated by the guide tool without drilling key is higher than that of the tool with drilling key.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.222.252.132