新型植入式脊髓电刺激系统在羊的生物安全性和组织相容性研究  被引量:3

Biosafety and histocompatibility of a new implantable spinal cord stimulation system in sheep

在线阅读下载全文

作  者:毛鹏[1] 李怡帆 李春蕊[3] 王志燕 化朋 王新星 王泊宁 樊碧发[1] 李路明[4] MAO Peng;LI Yi-Fan;LI Chun-Rui;WANG Zhi-Yan;HUA Peng;WANG Xin-Xing;WANG Bo-Ning;FAN Bi-Fa;LI Lu-Ming(Department of Pain Medicine,China-Japan Friendship Hospital,Beijing 100029,China;Graduate school of Beijing University of Chinese Medicine,Beijing 100029,China;Center of Day Surgery,China-Japan Friendship Hospital,Beijing 100029,China;National Engineering Laboratory for Neuromodulation,Tsinghua University,Beijing 100084,China;Department of Pain Medicine,People's Hospital of Dingzhou City,Dingzhou 073009,China)

机构地区:[1]中日友好医院疼痛科,北京100029 [2]北京中医药大学研究生院,北京100029 [3]中日友好医院日间手术中心,北京100029 [4]清华大学神经调控技术国家工程实验室,北京100084 [5]河北省定州市人民医院疼痛科,定州073009

出  处:《中国疼痛医学杂志》2020年第4期265-269,275,共6页Chinese Journal of Pain Medicine

基  金:国家重点研发计划-脊髓刺激治疗疼痛临床试验设计与组织(2016YFC0105504)。

摘  要:目的:验证新型植入式脊髓电刺激(spinal cord stimulation,SCS)系统的安全性、可操作性和组织相容性。方法:成年雄性小尾寒羊3只,在X线透视引导下行SCS植入术,植入穿刺电极、外科电极和脉冲发生器(implantable pulse generator,IPG),观察术后实验羊的行为学改变、血白细胞(white blood cell,WBC)水平、设备电阻抗值。在术后4周时取脊髓标本行苏木精-伊红(hematoxylin-eosin,HE)染色,观察SCS刺激节段与未刺激节段的脊髓结构。结果:实验羊的术后运动和感觉正常,术后WBC水平在正常范围内波动,术中、术后阻抗值正常,设备运转工作正常。与未刺激节段相比,刺激节段脊髓形态结构正常,未见明显细胞坏死、水肿、缺血、炎症等病理改变。结论:新型植入式SCS系统的生物安全性和可操作性良好,符合临床应用需求。Objective: To verify the safety, operability, and histocompatibility of the new implantable spinal cord stimulation(SCS) system. Methods: The SCS system was implanted in three small-tailed Han sheep under X-ray fiuoroscopy. The percutaneous leads, paddle leads, and implantable pulse generators(IPG) were placed. The postoperative animal behavioral changes and white blood cell(WBC) counts and impedance were accessed. Spinal cord specimens were taken four-week after operation for hematoxylin-eosin(HE) staining, and the spinal cord structures of SCS stimulated and unstimulated segments were compared. Results: The postoperative movement and sensation of the sheep were normal, the postoperative blood WBC counts fiuctuated within the normal range, the intraoperative and postoperative impedance values were typical, and the system operation was regular. Compared with the unstimulated segment, the morphological structure of the spinal cord in the stimulated segment was reasonable, and no apparent cell necrosis, edema, ischemia, infiammation, and other pathological changes were observed. Conclusion: The new implantable SCS system has excellent biological safety and operability, which meets the needs of clinical application.

关 键 词:脊髓电刺激 生物安全性 组织相容性 小尾寒羊 疼痛 

分 类 号:R741.05[医药卫生—神经病学与精神病学]

 