三相六开关容错逆变器驱动异步电机FCS-MPTC  被引量:7

Three-phase six-switch fault-tolerant inverter drives induction motor FCS-MPTC

在线阅读下载全文

作  者:缪仲翠[1,2] 余现飞 张文宾 李东亮 王志浩 MIAOZhong-cui;YUXian-fei;ZHANG Wen-bin;LI Dong-liang;WANG Zhi-hao(Department of Automation and Electrical Engineering,Lanzhou Jiaotong University,Lanzhou 730070,China;Gansu Provincial Engineering Research Center for Artificial Intelligence and Graphics&Image Processing,Lanzhou 730070,China)

机构地区:[1]兰州交通大学自动化与电气工程学院,兰州730070 [2]甘肃省人工智能与图形图像处理工程研究中心,兰州730070

出  处:《控制与决策》2020年第6期1377-1383,共7页Control and Decision

基  金:国家自然科学基金项目(61663022).

摘  要:针对异步电机驱动系统中三相六开关逆变器单管故障问题,提出一种逆变器在故障状态下的三相六开关容错控制策略,较三相四开关容错控制可以提供较多的电压矢量,进而可以有效抑制转矩脉动.结合有限集预测控制思想,提出一种基于三相六开关容错逆变器的异步电机有限控制集模型预测转矩控制策略,同时采用模糊PI转速控制器替代固定参数的PI控制器,进一步提高系统的稳定性、快速性和鲁棒性.仿真结果表明,采用此方案进行控制的异步电机驱动系统能够持续稳定运行,具有良好的动态性能,进一步验证了所提出方法的有效性.Aiming at the problem of single-tube fault of three-phase six-switch inverters in induction motor drive systems,a three-phase six-switch fault-tolerant control strategy of inverter under fault condition is proposed, which can provide more voltage vectors than three-phase four-switchs and then the torque ripple can be effectively suppressed. Combined with the idea of finite-set predictive control, a three-phase six-switch fault-tolerant inverter finite-control-set model predictive torque control(FCS–MPTC) strategy is proposed. At the same time, the fuzzy PI speed controller is used to replace the fixed-parameter PI controller to further improve the stability, rapidity and robustness of the system. The simulation results show that the induction motor drive system controlled by this scheme can continue to operate stably and has good dynamic performance, and further validates the effectiveness of the proposed method.

关 键 词:异步电机 三相六开关 容错控制 有限控制集模型预测控制 模糊PI 

分 类 号:TP273[自动化与计算机技术—检测技术与自动化装置]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象