检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Teresa Laborda-Guirao Juan M Cubero-Parra Antonio Hidalgo-Torres
机构地区:[1]Department of Glaucoma,Hospital La Arruzafa,Cordoba 14012,Spain
出 处:《International Journal of Ophthalmology(English edition)》2020年第8期1250-1256,共7页国际眼科杂志(英文版)
基 金:funded by Allergan S.A。
摘 要:AIM:To assess the effectiveness of the XEN 45 gel stent,either alone or combined with cataract surgery,in advanced stage open angle glaucoma(OAG)patients.METHODS:Retrospective and single-center study conducted on consecutive OAG patients who underwent a XEN 45 gel stent implantation surgery,between July 2017 and September 2018.The primary efficacy end-point was the mean intraocular pressure(IOP)reduction at the end of the follow-up period.Success was defined as an IOP reduction of at least 20%and an IOP value≤18 mm Hg without(complete)or with(qualified)hypotensive medication.RESULTS:Seventy-four patients(80 eyes)were included in the study.In the overall study sample,XEN implant significantly reduced IOP from 21.0(19.8 to 22.1)mm Hg at baseline to 9.3(8.2 to 10.4),10.7(9.6 to 11.9),13.4(12.2 to 14.7),14.5(13.6 to 15.4),14.7(13.8 to 15.6),and 14.7(13.9 to 15.4)mm Hg at 1 d,1 wk,1,3,6,and 12 mo of follow-up,respectively(P<0.0001 each).In the overall study population,at the end of the study the mean IOP reduction was 27.4%(23.3%to 31.5%).Adjusted IOP reduction was similar in XEN and XEN+phacoemulsification groups[30.0(23.4 to 36.4)mm Hg vs 24.8(18.4 to 31.2)mm Hg,respectively,P=0.2939].At the last follow-up visit,52(65.0%)eyes were considered success,29(36.3%)eyes as complete success and 23(28.7%)as qualified success.Mean number of hypotensive medications was significantly reduced from 2.8(2.7 to 3.0)at baseline to 1.1(0.8 to 1.3),P<0.0001.Kaplan-Meier survival analysis did not find any difference in the success rate between XEN and XEN+PHACO,mean hazard ratio 0.56,95%CI 0.26 to 1.23;P=0.1469.Needling was performed in 7(8.8%)eyes at months 1(n=3);3(n=2);4(n=1)and 11(n=1).Eleven(13.8%)eyes presented adverse events.CONCLUSION:XEN implant,either alone or in combination with phacoemulsification,significantly reduced the IOP and the number of hypotensive medications in patients with OAG in advanced stage.
关 键 词:open angle glaucoma advanced stage XEN implant intraocular pressure minimally-invasive glaucoma surgery
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.198