3D成像测量技术在SVF-gel注射隆颏术效果评估中的应用  被引量:1

Application of 3D imaging measurement technique in the evaluation of efficacy after chin augmentation by SVF-gel

在线阅读下载全文

作  者:王思越 罗赛[1] 董慧双 赵弘历 郝立君[1] WANG Si-yue;LUO Sai;DONG Hui-shuang;ZHAO Hong-li;HAO Li-jun(Department of Plastic Surgery,The First Affiliated Hos-pital of Harbin Medical University,Harbin 150001,China)

机构地区:[1]哈尔滨医科大学附属第一医院整形美容中心,黑龙江哈尔滨150001

出  处:《中国美容整形外科杂志》2020年第8期462-465,共4页Chinese Journal of Aesthetic and Plastic Surgery

摘  要:目的将3D成像技术应用于注射隆下颏的术前、术后即刻及术后6个月的测量,为临床颏部注射填充效果评估提供更完善的数据参考。方法自2018年7月至2019年1月,以脂肪干细胞胶(stromal vascular fraction-gel,SVF-gel)注射隆下颏进行面部轮廓重塑,符合入组条件32例,年龄18~45岁,用Artec Eva 3D扫描仪对颏部术前、术后即刻及术后6个月采集3D成像数据,并从线距、角度等方面进行对比,综合评估治疗效果并进行统计学分析。结果32例患者注射隆颏后未出现并发症,失访2例,共收集数据30例,对颏部塑形效果均较满意。基于本研究组制定的颏部3D成像测量评估指标,30例患者术前、术后即刻及术后6个月下颏冠状位、矢状位的线距、角度等数据变化值均具有统计学意义(P<0.01)。结论应用3D成像技术测量和评估颏部注射SVF-gel塑形手术的术后效果,较传统方法更直观、精确和客观,值得临床应用。Objective The 3 D imaging technology was applied to measure the chin augmentation before the injection,immediately after injection and at 6 months after injection,so as to provide a better data reference for the evaluation of chin augmentation in clinic.Methods From July 2018 to January 2019,chin augmentation by stromal vascular fraction-gel(SVF-gel)injection was performed.The 3 D imaging data of chin before the injection,immediately after injection and at 6 months after injection were collected by Artec Eva 3 D scanner.The efficacy was compared from the aspects of linear distance and angle,comprehensive assessment of therapeutic effect and statistical analysis were performed.Results Thirty-two patients received SVF-gel injection for chin augmentation.No complications were found.Follow-up was lost in 2 patients,and data were collected in 30 patients.Based on the measurement and evaluation indexes of 3 D mental imaging developed by our research group,the changes in the linear distance and angle of the coronary and sagittal mental positions of 30 patients before and immediately after injection and 6 months after injection showed a consistent trend and were statistically significant(P<0.01).Conclusion The application of 3 D imaging technology in the measurement and evaluation of postoperative efficacy of chin filling with SVF-gel was more intuitive and accurate than traditional methods.It should be considerable for clinical application.

关 键 词:颏部整形 注射SVF-gel 3D成像技术 3D测量方法 

分 类 号:R782.2[医药卫生—口腔医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象