电子时空影像关联技术在胎心检查中的应用价值  被引量:1

Application Value of Electronic Spatiotemporal Image Correlation Technique in Fetal Heart Examination

在线阅读下载全文

作  者:王彧[1] 齐禹 张颖[1] WANG Yu;QI Yu;ZHANG Ying(Department of Ultrasound,Shengjing Hospital of China Medical University,Shenyang 110004,China)

机构地区:[1]中国医科大学附属盛京医院超声科,辽宁沈阳110004

出  处:《中山大学学报(医学科学版)》2020年第5期781-787,共7页Journal of Sun Yat-Sen University:Medical Sciences

基  金:沈阳市科学技术计划项目(F16-206-9-11);中国医科大学青年骨干支持计划(指导计划类)项目(QGZD2018065)。

摘  要:【目的】比较电子时空影像关联(eSTIC)技术与常规时空影像关联(STIC)技术在显示胎儿心的结构中的应用价值。【方法】随机选取的2018年1月至2019年12月在我院进行产前胎心超声检查的180名孕妇。由一名经过培训的超声医生分别使用STIC与eSTIC技术获取入组胎儿心的容积数据并存储。由另两名经验丰富的超声医生对获取的容积数据进行线下分析,比较两种容积数据对正常心结构的显示率。【结果】eSTIC技术对胎儿四腔心切面(93.33%vs.78.33%)、左室流出道切面(87.22%vs.75.56%)、右室流出道切面(78.89%vs.66.11%)、三血管-气管切面(84.44%vs.70.56%)、主动脉弓切面(72.78%vs.60.00%)、动脉导管弓切面(81.11%vs.63.33%)、室间隔三维重建切面(81.67%vs.60.56%)、房室环重建切面(68.33%vs.51.11%)的显示率及心内各结构平均显示率(80.97%vs.65.69%)均明显高于STIC技术,差异有统计学意义(均P<0.01)。【结论】eSTIC技术获取的容积数据比STIC能提供更清晰的结构信息。eSTIC技术可以作为二维扫查的有效补充,提供二维难以直接显示的心结构,辅助临床诊断。【Objective】To compare the application value of electronic spatiotemporal image correlation(eSTIC)technology and conventional spatiotemporal image correlation(STIC)technology in displaying fetal heart structure.【Methods】A total of 180 pregnant women who underwent prenatal fetal cardiac ultrasound in our hospital from January 2018 to December 2019 were randomly selected.A trained sonographer used STIC and eSTIC technology to obtain and store volume data of the enrolled fetal hearts,respectively.Another two experienced sonographer performed an offline analysis of the obtained volume data and compared the display rates of the two volume data on normal cardiac structures.【Results】The visualization rate of fetal four-chamber view(93.33%vs.78.33%),left ventricular outflow tract view(87.22%vs.75.56%),right ventricular outflow tract view(78.89%vs.66.11%),three-vessel trachea view(84.44%vs.70.56%),aortic arch(72.78%vs.60.00%),ductal arch(81.11%vs.63.33%),3D rendering of complete intracardiac septa(81.67%vs.60.56%),3D rendering of atrioventricular annulus(68.33%vs.51.11%)and the average number of recogni⁃tions(80.97%vs.65.69%)obtained by eSTIC were all significantly higher than those of STIC(all P<0.01).【Conclusions】The volume data obtained by eSTIC technology can provide clearer structural information than STIC.The eSTIC technolo⁃gy can be used as an effective supplement to the two-dimensional scan clinically.

关 键 词:电子空间时间相关成像技术 产前诊断 胎儿心脏 容积数据 

分 类 号:R445.1[医药卫生—影像医学与核医学] R714.5[医药卫生—诊断学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象