作 者:王燕红 叶伟军[2] 詹时兆 欧阳翼[2] 曹新平[2] Wang Yanhong;Ye Weijun;Zhan Shizhao;Ouyang Yi;Cao Xinping(Department of Radiotherapy,The Second Affiliated Hospital of Fujian Medical University,Quanzhou 362000,China;Department of Radiotherapy,Sun Yat-sen University Cancer Center,State Key Laboratory of Oncology in South China,Collaborative Innovation Center for Cancer Medicine,Guangzhou 510060,China)
机构地区:[1]福建医科大学附属第二医院放疗科,泉州362000 [2]中山大学肿瘤医院放疗科华南肿瘤学国家重点实验室肿瘤创新协作中心,广州510060
出 处:《中华放射肿瘤学杂志》2020年第10期882-887,共6页Chinese Journal of Radiation Oncology
摘 要:目的探讨CT引导徒手腔内联合插植实现影像引导自适应后装(IGABT)相较于传统A点二维后装(CP)剂量学优势,明确其在宫颈癌治疗中的价值。方法选取在中山大学肿瘤医院行全量放疗的宫颈癌患者26例,每例患者行4次后装治疗。治疗时先徒手置入宫腔管及2根插植针,后增加插植针数量并调整方向、深度,分别行CT扫描获得2套图像。勾画高危临床靶区(HRCTV),A点和危及器官(直肠、膀胱及乙状结肠)。在2套图像上分别行CP和IGABT计划设计,并配对t检验、Wilcoxon检验两者剂量参数差异。结果以CP计划的覆盖指数(CI)进行分组,A组(CI≥0.90)包含20个CP和对应IGABT计划,B组(CI<0.90)包含84个CP和对应IGABT计划。A组的HRCTV体积及肿瘤直径明显小于B组(46.7cm3∶62.1cm3,P<0.001及3.1cm∶4.4cm,P<0.0001)。IGABT显著提高所有及B组D90%及覆盖指数,降低膀胱剂量,减少A组乙状结肠剂量,并改善剂量适形度及均匀性。结论IGABT能提高靶区覆盖、剂量适形度和均匀性,保护危及器官,且对肿瘤较大的患者仍有优势。Objective To analyze the dosimetric differences between CT-guided free-hand intracavity/interstitial brachytherapy[image-guided adaptive brachytherapy(IGABT)]and conventional point-A plan(CP)in the treatment of cervical cancer.Methods Twenty-six cervical cancer patients who received four cycles of IGABT in Sun Yat-sen University Cancer Center were enrolled in this study.Two sets of CT images were obtained before and after applicator adjustment to aid in the design of CP and IGABT plans.The high-risk clinical target volume(HRCTV),point A,and organs at risk(bladder,rectum,and sigmoid colon)were defined on CT images.CP and IGABT plans were designed on CT images.Parameter differences between CP and IGABT plans were analyzed with paired t-test and Wilcoxon test.Results According to the coverage index(CI)of CP,plans were divided into two groups:in group A(CI≥0.90),20 CP and corresponding IGABT plans were included,and 84 CP and corresponding IGABT plans in group B(CI<0.90).The mean volume of HRCTV and mean tumor diameter in group A were significantly smaller than those in group B(46.7 cm3 vs.62.1 cm3,P<0.001 and 3.1 cm vs.4.4 cm,P<0.001).Compared with CP,IGABT significantly improved the value of D90%in all plans and group B,whereas lowered the bladder dose.IGABT also reduced the dose of sigmoid colon in group A.IGABT significantly improved conformal index and dose homogeneity index.Conclusions IGABT can significantly improve the target coverage,conformal index and dose homogeneity index,protect organs at risk.Compared with CP,IGABT has advantages in the treatment of patients with bulky tumor.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.147.79.7