摘 要:医药工业洁净厂房采用粒子计数器,通过对单位体积空气中特定粒径悬浮粒子数量的测定,确定洁净室洁净度级别。本文介绍了医药工业洁净厂房室内悬浮粒子的检测方法,重点对测试条件、悬浮粒子采样、数据计算、结果判定、注意事项等进行了介绍,以便于确定洁净室洁净度是否达到GMP规范要求,满足生产需要。The pharmaceuticalindustryclean room uses particle counter to determine air cleanliness of cleanroom by measuring the number of airborne particle in specific volume of air in unit volume.This paper introduces the detection method of airborne particles in pharmaceutical clean room,focusing on the test conditions,airborne particles sampling,data calculation,result judgment,matters needing attention,etc.,so as to determine whether the air cleanliness achieve the GMP standard and meet the production needs.