对比增强能谱乳腺X线摄影诊断乳腺癌的价值  被引量:15

Value of Contrast Enhanced Spectroscopy Mammography in Diagnosis of Breast Cancer

在线阅读下载全文

作  者:封任冬[1] 李明伦 丁莹莹 马坚[1] 邓志春[1] 李润明 高琨 FENG Rendong;LI Minglun;DING Yingying(Department of Radiology,Yuxi First People’s Hospital(the Sixth Affiliated Hospital of Kunming Medical University),Yuxi,Yunnan Province 653100,P.R.China)

机构地区:[1]云南省玉溪市人民医院(昆明医医科大学第六附属医院)放射科,653100 [2]云南省肿瘤医院(昆明医科大学第六附属医院)乳腺外科,653100 [3]云南省肿瘤医院(昆明医科大学第六附属医院)病理科,653100 [4]云南省玉溪市红塔区妇幼保健院,653100 [5]云南省肿瘤医院(昆明医科大学第三附属医院)放射科,650118

出  处:《临床放射学杂志》2020年第7期1302-1307,共6页Journal of Clinical Radiology

摘  要:目的探讨对比增强能谱乳腺X线摄影(CESM)诊断乳腺癌的价值。方法回顾性分析经乳腺X线摄影(MG)筛查BI-RADS分类为4A类及以上病例进行乳腺CESM及MRI检查,并且最终经病理证实的50例52个病灶。所有患者均行双侧乳腺CESM和MRI检查。对病理标本进行判读,获得病理分类诊断结果,观察CESM和MRI表现,记录病灶检出情况,并对病灶进行定性诊断。以病理结果为金标准,采用卡方检验分析CESM及MRI的诊断效能。结果50例患者病理共检出52个病灶,良性病灶13个,恶性病灶39个;CESM检出病灶38个,MRI检出病灶34个,定性诊断判读错误病灶CESM 1个,MRI 5个。以病理结果为金标准,CESM诊断乳腺癌的敏感性、特异性和正确指数分别为97.40%、92.3%和0.897,MRI分别为87.2%、84.6%和0.718,差异均无统计学意义。结论CESM诊断乳腺癌与MRI检查的诊断效能接近。Objective To explore the value of contrast-enhanced energy spectrum mammography(CESM)in the diagnosis of breast cancer.Methods A retrospective analysis was performed on the cases classified as 4 A and above by BI-RADS by mammography-MG screening,and 50 cases with 52 lesions were finally confirmed by pathology.All patients underwent bilateral CESM and MRI examinations.Pathological specimens were interpreted to obtain the results of pathological classification,CESM and MRI were observed,the detection of lesions was recorded,and the qualitative diagnosis of lesions was made.The diagnostic efficacy of CESM and MRI was analyzed by chi-square test based on pathological results.Results There were 52 lesions,13 benign lesions and 39 malignant lesions in 50 patients.Thirty-eight lesions were detected by CESM and Thirty-four lesions were detected by MRI,and one of CESM and five of MRI was misinterpreted by qualitative diagnosis.With the pathological results as the gold standard,The sensitivity,specificity and accuracy indices of CESM in the diagnosis of breast cancer were 97.40%,92.3%and 0.897 respectively and MRI was 87.2%,84.6%and 0.718,respectively,There was no statistically significant difference between the two groups.Conclusion The diagnostic efficacy of CESM in breast cancer is similar to that of MRI.

关 键 词:对比增强能谱乳腺X线摄影 磁共振成像 乳腺癌 

分 类 号:R737.9[医药卫生—肿瘤] R730.44[医药卫生—临床医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象