检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:赖建东 王宁 罗坤 潘宁 朱亚男 周和平 张明 LAI Jiandong;WANG Ning;LUO Kun;PAN Ning;ZHU Ya'nan;ZHOU Heping;ZHANG Ming(Xi'an Jiaotong University Health Science Center,Xi'an 710061,China;Department of Medical Imaging,Ankang Central Hospital,Ankang 725000,China;Beijing Infervision Technology Inc,Beijing 100025,China)
机构地区:[1]西安交通大学医学部,陕西西安710061 [2]安康市中心医院影像科,陕西安康725000 [3]北京推想科技有限公司,北京100025
出 处:《中国医学影像技术》2020年第12期1781-1785,共5页Chinese Journal of Medical Imaging Technology
摘 要:目的探讨基于深度学习计算机辅助诊断系统(DL-CAD)测量脑出血量的应用价值。方法回顾性分析超急性期、急性期、亚急性期各50例脑出血患者脑部平扫CT资料,分别采用DL-CAD、多田公式法和CT定量法测量脑出血量,记录测量时间,并计算绝对百分误差率(APE)。比较3种方法测量结果、测量时间及APE差异。结果应用DL-CAD测量超急性期及亚急性期脑出血量结果与CT定量法差异无统计学意义(P均>0.05),而对急性期出血差异有统计学意义(P<0.05)。应用多田公式法测量脑出血结果与CT定量法差异均有统计学意义(P均<0.01)。采用DL-CAD测量不同时期脑出血量,测量时间均显著低于CT定量法及多田公式法(P均<0.01),且APE均低于多田公式法(P均<0.01)。结论与传统多田公式法相比,DL-CAD测量各期脑出血量准确性更高,且速度更快。Objective To explore the application value of deep learning-based computer aided diagnostic system(DL-CAD)in measuring the volume of cerebral hemorrhage.Methods Brain CT data of patients with cerebral hemorrhage in hyperacute,acute and subacute phases(each n=50)were retrospectively analyzed.DL-CAD,TEDA formula and CT quantitative method were used to measure the volume of cerebral hemorrhage,the measuring time was recorded and the absolute probability error(APE)was calculated.The measured results,the measuring time and APE of 3 methods were compared.Results There was no statistical difference between the measuring results of cerebral hemorrhage of hyperacute and subacute phases between DL-CAD and CT quantitative method(both P>0.05),while statistical difference of the acute phase was found(P<0.05).The results of cerebral hemorrhage measured using TEDA formula were statistically different from those of CT quantitative method(all P<0.01).The measuring time of DL-CAD for all periods cerebral hemorrhage were significantly lower than that of CT quantitative method and TEDA formula(all P<0.01).APE of cerebral hemorrhage measured with DL-CAD in all periods were lower than that of TEDA formula(all P<0.01).Conclusion DL-CAD could measure the volume of cerebral hemorrhage in all periods more quickly and accurately than traditional TEDA formula method.
关 键 词:脑出血 体层摄影术 X线计算机 深度学习 图像处理 计算机辅助
分 类 号:R743.34[医药卫生—神经病学与精神病学] R814.42[医药卫生—临床医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.227.89.169