检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:钟青松[1] 刘炜焜 陈嘉伟 张俊德[1] ZHONG Qingsong;LIU Weikun;CHEN Jiawei;ZHANG Junde(Department of Radiotherapy,Zhujiang Hospital of Southern Medical University,Guangzhou Guangdong 510282,China)
机构地区:[1]南方医科大学珠江医院放疗科,广东广州510282
出 处:《中国医疗设备》2021年第1期53-56,共4页China Medical Devices
摘 要:目的为了提高CT模拟定位图像与常规MRI扫描图像配准的精确度,使放疗靶区勾画的精确度提高,研制一套CT-MRI同体位放疗模拟定位装置。方法测量CT模拟定位固定装置的规格大小和MRI扫描机的床面大小、孔径大小等相关数据,根据测量数据选用凯夫拉、ABS塑料、尼龙螺丝材料设计并制造出CT-MRI同体位放疗模拟定位装置,包括MRI模拟定位体架、凹面床的平板适配床板和MRI体部扫描线圈拱形支撑架,分别用CT模拟定位固定装置、CT-MRI同体位放疗模拟定位装置对患者进行CT模拟定位和MRI模拟定位扫描,观察两组图像的配准融合效果。结果利用该装置安全、顺利完成MRI模拟定位扫描,经10例临床试验,CT-MRI同体位放疗模拟定位均能得到较好的图像配准融合效果。体位头部DICE:0.988,HD:3.340 mm;非同位头部DIC:0.947,HD:6.445 mm。同体位颈部DICE:0.847,HD:3.803 mm;非同体位颈部DICE:0.829,HD:4.679 mm。结论此CT-MRI同体位放疗模拟定位装置,能有效提高图像配准精确度,提高靶区勾画精确度,满足临床放疗要求。Objective In order to improve the accuracy of registration between CT simulated positioning image and conventional MRI scanning image,and improve the accuracy of delineation of radiotherapy target area,a set of CT-MRI simulative positioning device for radiotherapy in the same body position was developed.Methods Design the device by measuring the relevant data which include the specification of CT simulation positioning fixture,bed surface size and aperture size of MRI scanner.Based on the measurement data,Kevlar,ABS plastic,and nylon screws were selected to manufacture CT-MRI orthotopic radiotherapy positioning device,which consists of a body MRI simulation positioning frame,a flat bed adapting bed plate for a concave bed,and an arch support frame of MRI body scanning coil.In the end,CT simulated positioning fixture and CT-MRI orthotopic radiotherapy positioning device were used to perform CT simulated positioning and MRI simulated positioning for patients respectively,to observe the registration and fusion effect of CT and MRI images.Results The CT-MRI orthotopic radiotherapy positioning device achieved the MRI simulation positioning scan successfully and safely.And the device can obtain better image registration and fusion results after 10 clinical trials.DICE:0.988,HD:3.340 mm;Non-isotopic head DIC:0.947,HD:6.445 mm.DICE in neck with the same body position:0.847,HD:3.803 mm;DICE in neck with non-consomatic position:0.829,HD:4.679 mm.Conclusion The CT-MRI orthotopic radiotherapy positioning device satisfy clinical radiotherapy requirements,which can improve the precision of image registration effectively and improve the accuracy of the target delineation significantly.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15