检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:何柳媚[1] 陈浩 钟艳平[1] 全湛柔 邹红岩[1] He Liumei;Chen Hao;Zhong Yanping;Quan Zhanrou;Zou Hongyan(Institute of Transfusion Medicine of Shenzhen Blood Center,Shenzhen 518020,Guangdong Province,China)
机构地区:[1]深圳市血液中心输血医学研究所,广东省深圳市518020
出 处:《中国组织工程研究》2021年第25期4009-4012,共4页Chinese Journal of Tissue Engineering Research
摘 要:背景:人类白细胞抗原(human leukocyte antigen,HLA)高分辨确认工作是造血干细胞移植前必不可少的步骤之一,随着工作的不断深入开展及被检测人群的持续增加,人类白细胞抗原新等位基因不断涌现。有些新基因由于发现较晚,相关报道较少,导致基因频率不能准确计算,在缺乏相应数据的情况下,容易造成分型结果的误判,导致配型不相合结果,影响移植配型成功率。目的:对HLA一个等位基因HLA-A*24:353进行检测确认,并对其出现频率进行分析。方法:应用聚合酶链反应-直接测序分型方法对2019年9月至2020年5月间543例临床移植配型供受者进行HLA-A、-B、-C、-DRB1、-DQB1五个位点检测,再用第2代测序技术对HLA-A*24:02/24:353模棱两可结果进行全长序列测定,得到HLA高分辨分型结果,并计算HLA-A*24:353基因出现频率。结果与结论:检出HLA-A*24:02/24:353模棱两可结果146例,采用第2代测序技术进一步鉴定后,检出HLA-A*24:353基因5例,占A*24组的比例为3.42%,在543例检测人群中出现比例为0.92%。结果提示HLA-A*24:353在中国可能并不罕见,进行临床移植配型供受者高分辨分型时,当出现HLA-A*24:02/24:353模棱两可结果时,需做进一步确认,以增加分型结果的准确性,提高移植配型的成功率。BACKGROUND:High resolution validation of human leukocyte antigen(HLA)is one of the essential step before hematopoietic stem cell transplantation.With the continuous development of the work and the number of people tested continues to increase,human leukocyte antigen new alleles are constantly emerging.Due to the late discovery of some new genes and the lack of relevant reports,the gene frequency cannot be accurately calculated.In the absence of relevant data,it is easy to misjudge the typing results.The result of mismatch affects the success rate of transplantation.OBJECTIVE:An allele of HLA-A*24:353 was detected and confirmed in HLA,and its occurrence frequency was analyzed.METHODS:Polymerase chain reaction-sequencing-based typing method was used to detect five loci of HLA-A,B,C,DRB1,and DQB1 in 543 clinical transplantation matching recipients from September 2019 to May 2020.Next-generation sequencing was used to determine the full-length sequence of HLA-A*24:02/24:353 ambiguous results to obtain high resolution typing results of HLA and calculate the occurrence frequency of HLA-a*24:353 gene.RESULTS AND CONCLUSION:The ambiguous results of HLA-A*24:02/24:353 were detected in 146 cases.After further confirmatory tests using next-generation sequencing,the results of HLA-A*24:353 gene were detected in 5 cases(3.42%)in A*24 group and 0.92%in 543 cases.The results suggest that HLA-A*24:353 may not be rare allele in China.When HLA-A*24:02/24:353 ambiguous results appear in clinical transplantation matching recipients for high resolution typing,further confirmation is needed to increase the accuracy of typing results and improve the success rate of transplantation matching.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.49