居安思危,谈医院门诊诊室空调系统的平疫结合新方案  

New scheme of combining epidemic prevention with air conditioning system in outpatient clinic

在线阅读下载全文

作  者:朱喆[1] Zhu Zhe(Shanghai Institute of Architectural Design and Research Co.,Ltd.)

机构地区:[1]上海建筑设计研究院有限公司

出  处:《制冷与空调》2021年第5期67-70,共4页Refrigeration and Air-Conditioning

摘  要:大型医院门诊一般采用风机盘管+新风的系统,由于多种原因,门诊内的空气品质欠佳,医生们有改善工作环境的强烈愿望,为了改变这个现状,并不明显增加系统造价,笔者进行分析、计算,探索一个可灵活应对诊室内环境的系统。本文结合实际工程讲述了这个系统的由来、组成和相关计算,希望能给医院项目的设计人员提供参考。The primary air fan coil-unit system is generally used in outpatient department of large hospitals.Due to various reasons,the air quality in outpatient department is not good,and doctors have strong desire to improve working environment.In order to change this situation,the author makes analysis and calculation to explore a flexible system to deal with the indoor environment without additional cost.This paper describes the origin,composition and related calculation of this system to provide reference for the designers of hospital project.

关 键 词:风机盘管 全空气 诊室 