检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:J.H.Zheng Jun Huang Shan Deng Q.H.Wu Mengshi Li Xiaoxin Zhou Zhaoxia Jing
机构地区:[1]School of Electric Power Engineering,South China University of Technology,Guangzhou 510006,China [2]China Electric Power Research Institute,Beijing 100192,China
出 处:《CSEE Journal of Power and Energy Systems》2019年第4期454-465,共12页中国电机工程学会电力与能源系统学报(英文)
基 金:The work was supported by the State Key Program of National Natural Science Foundation of China(Grant No.51437006);the Natural Science Foundation of Guangdong Province,China(2018A030313799).
摘 要:The accuracy of the simulation model has a pro-found impact on the optimal operation of the energy hubs(EHs).However,in many articles,the constant model of the efficiency of equipment is adopted to formulate the operation system,which would probably lead to a simplification of the simulation models.But,EHs are typically operated under off-design condition due to the fluctuations in cooling,heating,electricity requirement.More-over,even though the off-design characteristics are considered,few studies have suggested comparing the differences between those two models by considering the operation cost.In order to assess the effect of the off-design characteristics of EH on the optimal operation accuracy in this paper,two test cases are performed on the fixed and variable load conditions,respectively.In addition,the individual effect of off-design characteristics of each equipment on the optimal operation cost of the EH is also investigated through four optimization runs.It is worth mentioning that the optimal operation problem of the EH considering the off-design characteristics and on-off status of the equipment is a mixed integer non-linear programming problem(MINLP).By testing the design and off-design models on the two cases,the results of simulation demonstrate that the optimal operation cost for the off-design model is larger than that for the design model.Nonetheless,in the aspect of the authenticity of the system operation strategy,the off-design model performs better than the design model.Furthermore,a larger relative error of the system operation cost between the two models can be observed when the EH is operated under a relatively lower load condition,revealing that the influence of off-design characteristic on the optimal operation of EHs is too significant to be neglected.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.143.203.223