Evaluating newer generation intraocular lens calculation formulas in manual versus femtosecond laser-assisted cataract surgery  被引量:2

在线阅读下载全文

作  者:Harrish Nithianandan Soumya Sharma Eric S.Tam Hannah Chiu Rajiv Maini Sohel Somani 

机构地区:[1]Department of Ophthalmology&Visual Sciences,McGill University,Montreal H4A 3S5,Canada [2]Ryerson University,Toronto,Ontario M5B 2K3,Canada [3]Department of Ophthalmology,University of Toronto,Toronto M5T 3A9,Canada [4]Uptown Eye Specialists,Vaughan,Ontario L4K 2Z5,Canada [5]William Osler Health System,Brampton,Ontario L6R 3J7,Canada

出  处:《International Journal of Ophthalmology(English edition)》2021年第8期1174-1178,共5页国际眼科杂志(英文版)

摘  要:AIM:To determine the refractive accuracy of the Haigis,Barrett Universal II(Barrett),and Hill-radial basis function 2.0(Hill-RBF)intraocular lens(IOL)power calculations formulas in eyes undergoing manual cataract surgery(MCS)and refractive femtosecond laser-assisted cataract surgery(Re LACS).METHODS:This was a REB-approved,retrospective interventional comparative case series of 158 eyes of 158 patients who had preoperative biometry completed using the IOL Master 700 and underwent implantation of a Tecnis IOL following uncomplicated cataract surgery using either MCS or ReLACS.Target spherical equivalence(SE)was predicted using the Haigis,Barrett,and Hill-RBF formulas.An older generation formula(Hoffer Q)was included in the analysis.Mean refractive error(ME)was calculated one month postoperatively.The lens factors of all formulas were retrospectively optimized to set the ME to 0 for each formula across all eyes.The median absolute errors(MedAE)and the proportion of eyes achieving an absolute error(AE)within 0.5 diopters(D)were compared between the two formulas among MCS and ReLACS eyes,respectively.RESULTS:Of the 158 eyes studied,64 eyes underwent MCS and 94 eyes underwent ReLACS.Among MCS eyes,the MedAE did not differ between the formulas(P=0.59),however among ReLACS eyes,Barrett and Hill-RBF were more accurate(P=0.001).Barrett and Hill-RBF were both more likely to yield AE<0.5 D among both groups(P<0.001).CONCLUSION:The Barrett and Hill-RBF formula lead to greater refractive accuracy and likelihood of refractive success when compare to Haigis in eyes undergoing Re LACS.

关 键 词:PHACOEMULSIFICATION CATARACT femtosecond laser intraocular lens 

分 类 号:R779.6[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象