三种PIVKA-Ⅱ试剂的临床诊断效能评价  

Clinical performance comparison of 3 PIVKA-Ⅱ detection reagents

在线阅读下载全文

作  者:姜菲菲[1] 王颖[1] 贾泳梅 郭秋艳[1] 刘宁[1] 于艳华[1] 赵艳[1] 娄金丽[1] JIANG Feifei;WANG Ying;JIA Yongmei;GUO Qiuyan;LIU Ning;YU Yanhua;ZHAO Yan;LOU Jinli(Department of Clinical Laboratory Center,Beijing Youan Hospital,Capital Medical University,Beijing 100069,China)

机构地区:[1]首都医科大学附属北京佑安医院临检中心,北京100069

出  处:《胃肠病学和肝病学杂志》2021年第8期915-918,共4页Chinese Journal of Gastroenterology and Hepatology

基  金:国家科技重大专项(2018ZX10302205-003);首都医科大学附属北京佑安医院中青年人才孵育项目(青年类)(YNKTQN20180205)。

摘  要:目的比较三种PIVKA-Ⅱ检测试剂的临床诊断效能,为检测机构选择提供参考依据。方法收集健康对照组、慢性乙型肝炎组(慢乙肝)、肝硬化组和肝癌组四组临床血清样本,分别用三种不同试剂进行PIVKA-Ⅱ检测,对检测结果进行一致性、分布情况、诊断效能分析。结果共收集217例临床血清样本,其中健康对照组33例、慢乙肝组33例、肝硬化组86例和肝癌组65例,各组男女比例差异无统计学意义(P>0.05)。三种试剂中,Abbott和Fuji检测结果具有较好的一致性(R2=0.84,P<0.05)。Roche与Abbott、Fuji的离群值多分布于肝癌组样本,且为PIVKA-Ⅱ高值样本。在肝癌诊断中,ROC分析显示Abbott、Fuji和Roche的AUC分别为0.882、0.878、0.857,最佳临界值分别为56.67 mAU/ml、68.00 mAU/ml、26.41 ng/ml。结论三种试剂均具有良好的临床诊断效能,其中Abbott和Fuji具有较好的一致性。Roche与Abbott、Fuji的离群值多分布于肝癌高值样本。Objective To compare the clinical diagnosis efficiency of 3 PIVKA-Ⅱdetection reagents,and provide a reference for testing institutions selection.Methods Clinical serum samples were collected from healthy control group,chronic hepatitis B(CHB)group,liver cirrhosis group and liver cancer group patients.PIVKA-Ⅱwas detected by 3 different detection reagents,and compared in consistent,distribution characteristics and diagnosis efficiency.Results A total of 217 clinical serum samples were collected,including 33 healthy controls patients,33 CHB patients,86 cirrhosis patients,and 65 liver cancer patients.There was no significant difference in gender among the groups(P>0.05).The results of Abbott and Fuji had a good consistency(R2=0.84,P<0.05).The outlier values of Roche to Abbott and Fuji were mostly distributed in the liver cancer group,as well as in the high-value PIVKA-Ⅱsamples.In ROC analysis of liver cancer diagnosis,the AUC of Abbott,Fuji and Roche were 0.882,0.878 and 0.857,respectively.The optimal cut-off values were 56.67 mAU/ml,68.00 mAU/ml and 26.41 ng/ml,respectively.Conclusion All the three reagents showed good clinical diagnostic efficacy,Abbott and Fuji showed good consistency.The outlier values of Roche,Abbott and Fuji were mostly distributed in the high-value PIVKA-Ⅱliver cancer samples.

关 键 词:PIVKA-Ⅱ 肝癌 诊断效能 性能比较 

分 类 号:R575[医药卫生—消化系统]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象